SMC Corporation of America
Elite Part Number Search
Search Results "ASP330F-01-08S-J"

Other parameter settings Front protective cover (Model: ZS-26-01) Normal operation mode Item Default setting Item Default setting [F80] Power saving mode OFF [F 3] Digital filter setting [F 4] Auto-preset function [F 5] Auto shift setting [F 6] Fine adjustment of display value 0.00 sec.

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) 2, Preparation of OUT1 device Prepare the sensor for which OUT1 is to be set. ON OFF Selection of Pressure range, Output style, Response time and Pressure setting method.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) [F20] Setting of external input Accumulated flow external reset [F22] Setting of analogue output Free range analogue output for instantaneous flow: OFF * Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Panel mount adapter (Part number: ZS-26-B) Front protective cover (Part number: ZS-26-01) *1: The panel mount adapter can be rotated through 90 degrees for mounting. *2: The panel mount adapter should be fixed firmly with screws. Otherwise, fluids such as water may enter After the product makes contact with the panel, the screws should be further tightened 1/4 to 1/2 turn.

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-28No.EX-OMN0011-F (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-34No.EX-OMO0030-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

Slave1 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 6320 01 20 (Object 6320h Sub-Index 1, length 32-bit) 1600h_sub2 = 6320 02 20 (Object 6320h Sub-Index 2, length 32-bit) Slave2 Mapping (1600h RPDO Mapping Parameter) 1600h_sub0 = 2 1600h_sub1 = 0007 00 20(Object 0007h (Unsigned 32) Sub-Index 0, length 32-bit) 1600h_sub2 = 6320 01 20(Object 6320h Sub-Index 1, length 32

M3 M5 01 N01 R04 R06 IM5 IM5H M5 female M5 female Port size M3x0.5 M5x0.8 R1/8 NPT1/8 M5x0.8 4 6 thread, thread, through M5x0.8 reducer reducer through type (with type mounting hole) Case Resin case: PBT Fitting: C3604BD PBT Resin case: PBT Resin case: PBT Fitting: SUS303 Fitting: A6063S-T5 Material Pressure sensing section Pressure sensor: Silicon, O-ring: NBR Oil resistance vinyl cabtyre

Front protective cover ZS-27-01 -7No.SFOD-OMO0004-B Summary of Product parts Names of individual parts Output (OUT1) display (Green): Lit when OUT1 is ON. Output (OUT2) display (Red): Lit when OUT2 is ON. LCD display: Displays the current status of charged potential, set mode condition and error code.

How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) : The panel mount adapter can be rotated by 90 degrees for mounting. : Front panel of this Controller meets IP65 (if 48 conversion adapter is used, it meets IP40).

Description Materials Bonnet Aluminum die-cast Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply diaphragm Weather resistant NBR Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, stainless steel, HNBR Body Aluminum die-cast Grease: lithium grease -7- How to order IR 0 0 01 BG A 0 1

Option Rated voltage Voltage symbol Part no. 100 VAC 100V VK300-82-2-01 110 VAC 110V VK300-82-2-03 200 VAC 200V VK300-82-2-02 Note) When requiring a gauge different than that mentioned above, specify the model number. 220 VAC 220V VK300-82-2-04 Option is packed with it.

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-40No.EX-OMP0013-E (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

Inch size Metric size 3.2 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 With One-touch fittings Use 1/8" tube. 15-9-72 2 Speed Controller with One-touch Fittings Panel Mount Type, In-line Type Needle Valve/Flow Characteristics AS1001F AS2001F AS2051F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR))

Metric size Inch size P . 15-11-3 3.2 With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Use 1/8" tube. 23 04 06 08 10 12 01 03 05 07 09 11 13 4 6 8 10 12 Flow Direction Symbols on Body JIS Symbol Symbol 15-9-10 2 Speed Controller with One-touch Fittings In-line Type Series AS Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5

/4 Piping port size NPT 1/8, 1/4 Pressure gauge port size 435 (3.0) Proof pressure psig (MPa) 290 (2.0) Maximum operating pressure psig (MPa) ARX20-N02 7~120 (0.05 to 0.85) Standard Regulating pressure range psig (MPa) 7~45 (0.05 to 0.3) Low pressure Fluid Air ARX20-N01BG Ambient and fluid temperature 23~140F ( 5 to 60C) (with no freezing) Weight lbs (Kgf) .24 (0.11) How to Order ARX2 0 01

/I.D. mm 8/5 9/6 10/6.5 12/8 12.5/8.5 16/11 Symbol 01 02 03 04 06 Symbol 50 60 65 80 85 110 Symbol 04 06 08 10 12 16 Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Tubing O.D. mm 4 6 8 10 12 16 Construction Description Material Plug Description Material Socket Note Note Electroless nickel plated No. 1 14 15 No. 1 2 3 4 5 6 7