If it does not locked easily, turn the handle s l i g h t l y c l o c k w i s e o r counterclockwise; then, push it until the orange colored line is no longer visible.
VY1A00 1, VY1B00 1 (Pilot valve: VY1D00-00) Working principle The supply (P to A) valve of valve y and the exhaust (A to R) valve close due to the balance between actuating forces F1 and F2.
Pressure Switch Calibration Withstand voltage 10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s2 (at the smaller vibration) in X, Y, Z directions (2 hours) Vibration resistance Use the calibration adjustment to set ON pressure. Rotate clockwise to increase pressure setpoint. For setting vacuum, rotate counterclockwise.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of needle rotations Number of needle rotations Number of needle rotations Construction t r w e With reducer q i A y u y u Part lists y Description No.
C.O. type does not have a return spring y. 12 (P1) port 10(P2) port Working Principle (Vacuum pilot type is excluded) VNB0 , 1 (N.C.)
Then valve element B y connected to the valve element A t is open. When the pilot operated solenoid valve !2 is energized, the pilot air supplied to the bottom of the piston u moves upward to open the valve element A t and closes the valve element B y. Because rod !0 is connected to valve element A t by parallel pin !1.
Note 2) Value on option V, R, Y (Nonleak, Vacuum). Note) The value is the case of no grease applied on armature. 17-3-88 3 Series VVX31/32/33 Direct Operated 3 Port Solenoid Valve/Manifold For Air, Gas, Vacuum and Oil The models VX31/32/33 have been revised. For details, please refer to catalog no. ES70-26A. Similar updating for other VX series are scheduled to follow shortly.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VXD2272/2382/2392 VXD2270/2380/2390 Operation
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VXP2272/2382/2392 VXP2270/2380/2390 Operation
Standard BC6 BC6 NBR Stainless steel, Brass NBR Standard BC6 BC6 NBR Stainless steel, Brass NBR Body Bonnet O-ring Diaphragm assembly Valve spring Body Bonnet O-ring Diaphragm assembly Valve spring q w e q w e FKM Stainless steel, Brass FKM FKM Stainless steel, Brass FKM r r Stainless steel Stainless steel t t y Core assembly Stainless steel, Copper y Core assembly Stainless steel,
If it is smaller, air leakage will occur due to back pressure. y q w !4 SlA !7 !4 3(R) VlA !1 e 3(R) Effective area (mm2) Model Component Parts VHS 2500, 3500 5 VM/VR Description Material ADC12 ZDC2 ADC12 Zinc alloy Zinc alloy C3604B A2017B C3604B Description No. q w e r t y u i No. !0 !1 !2 !3 !4 !5 !6 !7 !
lead wire length: 600mm) D-DIN type terminal 4 5 6 7 9 Order made Port size M5 01 M5 x 0.8 Rc(PT) 1/8 (port A) VKF332 (with bracket) Body ported (single type) 5 G M5 Body ported (for manifold) 5 G M5 VKF333 5 G 01 VKF334 Base mounted Light/Surge voltage suppressor Valve option Port size For vacuum For low power consumption For vacuum/low power consumption For long loading time 01 Nil V Y
Description Standard Brass Body Valve assembly Piston assembly Piston spring Stainless steel q Stainless steel FPM/EPR Stainless steel, Brass, NBR, Polyacetal w e r Polyacetal/NBR y t O ring Pilot cover NBR Aluminium Stainless steel FPM/EPR 4.1-58 VXA21/22 How to Order VXA22 VXA21 Bracket Model B None With bracket Select a model from the highest operating pressure difference and the characteristic
Component Parts Description Outer tube Piston rod Piston Bearing Return spring Stopper Material Rolled steel Special steel Special steel Description Check ball Accumulator Rod seal Scraper Bumper Material Bearing steel Fluoro rubber NBR NBR Polyurethane Treatment Treatment Black nickel plated Heat treated, Hard chrome plated Heat treated No. q w e r t y No. u i o !0 !
0 y !5 !4 @2 !3 w @4 @3 !6 !7 !8 !1 @1 !2 q @0 u !
+X +Y X Y End deflection (when extended) + Non-rotating accuracy 5 Compact Cylinder with Linear Guide MXZ Series Mounting Bolt Mounting Bolt for MXZ When using through holes, use the mounting bolts from the CQ series. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Example) CQ-M3 x 25 L 2 pcs.
Connector block assembly (For 9 to 17 stations (T1) terminal block) t-6 SX5000-64-8A SX3000-64-8A M3 x 30 (Matt nickel plated) SX3000-22-2 (M2 x 24) SX5000-57-6 Round head combination screw y Gasket DIN rail SX3000-57-4 VZ1000-11-1u i Refer to page 1-6-77. Note) The numbers t1 to 4 are for 24 VDC. For 12 VDC, suffix -12V to the parts no.
Connector block assembly (For 9 to 17 stations (T1) terminal block) t-6 SX5000-64-8A SX3000-64-8A M3 x 30 (Matt nickel plated) SX3000-22-2 (M2 x 24) SX5000-57-6 Round head combination screw y Gasket DIN rail SX3000-57-4 VZ1000-11-1u i Refer to page 1-6-77. Note) The numbers t1 to 4 are for 24 VDC. For 12 VDC, suffix -12V to the parts no.
0.40 2.2 Exhaust center 3 position 354 9.2 [3.0] 0.50 [0.49] 2.6 [0.85] 6.1 0.35 1.6 Pressure center Note 1) [ ]: Normal position Note 2) Values without bracket 1500 VFA1000/3000/5000 Series 5 Port Air Operated Valve Body Ported/Single Unit Construction: Body Ported 2 position single VFA1000 VFA3000, 5000 Symbol 2 position single VFA1000 t qe r q e (B)2 4(A) SYA w (B) 2 (A) 4 (A) 4 (B) 2 w y