Solenoid valve drive for AC with solid state output (SSR, TRIAC output, etc.) 1) Current leakage When using a snubber circuit (C-R element) for surge protection of the output, a very small amount of electrical current will continue to flow even during the OFF state. This results in the valve not returning.
<AC> There is no S option, since a rectifier prevents surge voltage generation.
Light/Surge Voltage Suppressor (VEX1501, 1701, 1901) Caution AC DC Electrical Connection (VEX1501, 1701, 1901) DIN terminal is connected inside as in the figure below. Connect to the corresponding power supply.
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
Electrical entry direction Perpendicular Perpendicular Perpendicular Wiring type 3-wire 2-wire IC circuit, Relay, PLC Applicable load IC circuit Relay, PLC AC DC 24V or less/50mA Load current range and Max. load current 24VDC/5 to 40mA 100VAC/5 to 20mA Load valtage AC DC AC DC 4 to 8VDC/20mA 48V or less/40mA 100V or less/20mA Contact protection circuit None 2.4V or less (to 20mA) 3V or less
Auto Switch Specifications Grommet Electrical entry:In-line PLC: Programable Logic Controller D-A90, D-A90V (without indicator light) D-A90, D-A90V Switch model Applicable load IC circuit, Relay, PLC Load voltage AC DC AC DC AC DC 24 V or less 48 V or less 100 V or less Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 3 m) Internal
Common Specifications Reed switch Solid state switch Style None 3 wire style: 100 mA or less 2 wire style: 1mA or less Current leakage 1 ms or less (2) 1.2ms Operating time 300m/s2 1000m/s2 Shock resistance 50M or more at 500V DC (Electrical wire, Between bowls) Insulation resistance 1 minute at 1500V AC(1) (Electrical wire, Between bowls) 1 minute at 1000V AC (Electrical wire, Between bowls
Applicable load IC circuit, Relay, PLC Load voltage 24V or less 48V or less 100V or less AC DC AC DC AC DC Maximum load current 50mA 40mA 20mA Contact protection circuit None Internal resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) 1 or less (including 3m lead wire length) D-A93, D-A93V D-A96, D-A96V Auto switch part no.
Teaching box Controller Series LC1 Regenerative absorption unit Series LC7R 1 Short stroke type with three guide variations Short Stroke Electric Actuators Series LX Low profile slide table type with stepper motor Series LXF Space saving Thickness:31mm Guide rod type with stepper motor Series LXP Use as lifter High rigidity slide table type with stepper motor Series LXS High moment load AC
Model IS1000-01 0.1 to 0.4MPa Set pressure range (OFF) 0.08MPa Differential 1a Contact point construction 2VA AC, 2W DC Max. contact point capacity 48V 100V 12V 24V Voltage (AC, DC) 40mA 20mA 50mA 50mA Max. current 1.2ms Operating time 30G Shock resistance JIS symbols w AMR4000 AMR3000 AMR5100 1.9-1 Regulator with Mist Separator AMR3000 to 6000 How to Order Adapter Assembly (part number for
D-Z80 Electrical entry direction In-line Applicable load Relay, PLC, IC circuit AC DC AC DC AC DC 100V Load voltage 24V or less 48V Maximum load current 50mA 40mA 20mA Contact protection circuit None 1 or less (including lead wire length of 3m) Internal resistance Lead wires Oil resistant vinyl heavy duty cord, 3.4, 0.2mm, 2 wire [Brown, Blue (Red, Black)], 3 wire [Brown, Black, Blue (Red
D-Z80 Electrical entry direction In-line Applicable load Relay, PLC, IC circuit AC DC AC DC AC DC 100V Load voltage 24V or less 48V Maximum load current 50mA 40mA 20mA Contact protection circuit None 1 or less (including lead wire length of 3m) Internal resistance P Lead wires Oil resistant vinyl heavy duty cord, 3.4, 0.2mm, 2 wire [Brown, Blue (Red, Black)], 3 wire [Brown, Black, Blue (
D-Z80 Electrical entry direction In-line Applicable load Relay, PLC, IC circuit AC DC AC DC AC DC 100V Load voltage 24V or less 48V Maximum load current 50mA 40mA 20mA Contact protection circuit None 1 or less (including lead wire length of 3m) Internal resistance P Lead wires Oil resistant vinyl heavy duty cord, 3.4, 0.2mm, 2 wire [Brown, Blue (Red, Black)], 3 wire [Brown, Black, Blue (
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 VT VP 3 1 AC DC VG Rated voltage Allowable voltage range Coil insulation Inrush Holding Power consumption DC VP Double solenoid 2 Electrical entry S070 Apparent power AC (Power consumption) VQ Grommet, Grommet terminal, Conduit terminal, DIN terminal
External pilot Apparent power VA (Hz) AC Holding When changing the passage state, confirm that pressure has been removed from the valve. Unscrew the M4 x 0.7 hexagon socket head cap screw in the changeover plate and match the mark on the adapter plate with the character on the changeover plate. Piping is as follows.
Filter regulator and lubricator unit , Clean looking, modular design , Improved installation , Compact spacer with bracket reduces total assembly space , Optional embedded pressure gauge , Rc(PT), G(PF) or NPT threads AC MASS PRO. AC MASS PRO 1/4 MODULAR (NPT). AIRLINE EQUIPMENT. AC MASS PRO 1/4 MODULAR (NPT). 1.31443 lb. DC.
Filter regulator and lubricator unit , Clean looking, modular design , Improved installation , Compact spacer with bracket reduces total assembly space , Optional embedded pressure gauge , Rc(PT), G(PF) or NPT threads AC MASS PRO. AC MASS PRO 1/4 MODULAR (NPT). AIRLINE EQUIPMENT. AC MASS PRO 1/4 MODULAR (NPT). 1.54323 lb. DC.
Filter regulator and lubricator unit , Clean looking, modular design , Improved installation , Compact spacer with bracket reduces total assembly space , Optional embedded pressure gauge , Rc(PT), G(PF) or NPT threads AC MASS PRO. AC MASS PRO 1/4 MODULAR (PT). AIRLINE EQUIPMENT. AC MASS PRO 1/4 MODULAR (PT). 2.44409 lb. DA.
Filter regulator and lubricator unit , Clean looking, modular design , Improved installation , Compact spacer with bracket reduces total assembly space , Optional embedded pressure gauge , Rc(PT), G(PF) or NPT threads AC MASS PRO. AC MASS PRO 1/4 MODULAR (NPT). AIRLINE EQUIPMENT. AC MASS PRO 1/4 MODULAR (NPT). 1.98416 lb. DC.