M5 A 3(R) EXE H A mm Model A B C D E Fn Fd G H XLDV25 50 123 48 41.5 7.5 40 26 38.5 XLDV40 65 170 66 53.5 15.0 55 41 48.5 XLDV50 70 183 79 57.5 17.5 75 52 55.0 XLDV63 88 217 100 72.2 20.0 87 95 70 66.5 XLDV80 90 256 117 82.6 26.5 114 110 83 75.0 XLDV100 108 321 154 95.2 38.0 134 130 102 93.5 XLDV160 138 335 200 101.2 40.0 190 180 153 116.5 10 XL-OMM0005-A 6 Period and Scope of Warranty The
a0~60 b25~85%RH c d e 5. f g. h i 6. j k L 2. 7. 8. 1. 9. 2. 10. 11. ()70% ()35% 1. 15% 1. 2. 3 3. () 1. 0.1~1.0MPa 0.3~0.5MPa 0~60 ()35% 2. ) 1. 1. 2. 2. 3. 1. 1. ( 2. 6 ) 3. 2. 50% 4. (6 ) 3. 5. 4. () 0.5 5. 1 2 3. F.G. 1. 4. 1 ISO VG32 1. 2. 1. 2. 3. 1. 2 1. 2. 2. 14.5mT CE2 1.5~2 15,000 18cm 3. 4. IP65 5.
Measures should be taken to prevent drop of hanging or lifing equipment. h. Place where static electricity is discharged or condition that the products have electrostatic discharge. i. Place where strong high frequency is gene-rated. j. Place where damages of thunder are expected. k. Place where vibration or impact is directly 6.
( ) f. g.( ) h. i. j. k. l. 4. 4. 4. 4. 5. 5. 5. 5. 6. 6. 6. 6. 7. 7. 7. 7. 2. 2. 2. 2. 8. 8. 8. 8. ,, 1. 1. 1. 1. 9. 9. 9. 9. 2. 2. 2. 2. - 10. 11. ( )70% ( )35% 1. 1. 1. 1. 1. 1. 1. 1. 2. 2. 2. 2. 3 1. 1. 1. 1. 0.10.8MPa 0.30.5MPa :560 3. 3. 3. 3. ( ( ( ( ) ) ) ) 2. 2. 2. 2. 35% ) 1. 1. 1. 1. 5 2. 2. 2. 2. - 1. 1. 1. 1. 1. 1. 1. 1. ( ( ( ( 6 6 6 6 ) ) ) ) 2. 2. 2. 2. 3. 3. 3. 3. 2
mm M(D)HR3-10 M3x0.5 0.88 6 9h9 0 0.036 1 M(D)HR3-15 12h9 0 0.043 1.5 8 Lateral side mounting Location pin hole Model Mounting bolt Max. tightening torque Nm Max. screw-in depth (l) mm Hole Height h mm diameter d mm M(D)HR3-10 M3x0.5 0.88 6 3 +0.02 0 6 M(D)HR3-15 Vertical side mounting Location pin hole Model Mounting bolt Max. tightening torque Nm Max. screw-in depth (l) mm Hole Height h
LEG*-OMZ0023-B PRODUCT NAME Electric Actuator / Guide type Battery-less absolute (Step motor 24VDC) MODEL / Series / Product Number LEG Series Applicable models LEG(25,32,40) Controller H Series #This manual describes the actuators operation in combination with the JXC*H series controllers. #Refer to the manual relevant to the controller being used for full operating instructions.
ILS PTC Starter(Start Relay) PTC Magnetic Contactor MC THS Thermostat TB Terminal Block Temperature Controller TC Temperature Sensor TS Solid State Relay SSR Heater H Fuse F Ground Fault Circuit Interrupter GFCI Programable Logic Controller PLC 64 IDH Series 6.4 Electrical Wiring Diagrams IDX-OM-W037 Thermo-dryer 6.
Object instance Present value of maintenance counter 0 to 4294967295 (0 to F H) 0x66 Maintenance Counter Maintenance counter threshold over flag 0: Maintenance counter 0x67 Maintenance Counter Exceed value < Threshold 1: Maintenance counter value > Threshold Threshold of maintenance counter 0 to 4294967295 (0 to F H) The set value is immediately reflected. 0x68 Threshold Maintenance Counter
(Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation. Mode where the switch output will turn ON when the flow is greater than the set value, and will turn OFF when the flow falls below the set value by the amount of hysteresis or more.
H: Contents are added. I: Contents revised in several places.[March 2017] J: Contents revised in several places.
Gripping point Gripping point Gripping point Good: "L" and "H" are appropriate Not good: "L" is too long Not good: "H" is too long (1) A long or heavy attachment increases the inertia force required to open or close the fingers.
Exterior dimensions C D XMA Series Angle Valve Fd Fn Fc C Fc L1 KF Flange K Flange CF Flange ( K ) ( K F ) ( C F ) L2 H B G A A Unit:mm Model n Fd Fc H P.C.D L1 L2 XMA-16 40 103 38 1 30 34 17 40 P.C.D 27 6x4.4 XMA-25 50 113 48 1 40 26 39 XMA-40 65 158 66 2 55 70 41 63 P.C.D. 58.7 6x6.6 XMA-50 70 170 79 2 75 52 68 XMA-63 88 196 100 3 87 95 114 70 69 P.C.D. 92.1 8x8.4 XMA-80 90 235 117 3 114
L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 40 20 80 60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang
MXH MXH Vertical Horizontal MXS L1: Load eccentricity MXQ m Mounting orientation m MXQ L H MXF L H MXW Maximum speed (mm/s) Up to 100 Up to 300 x Up to 500 Up to 100 100 b 50 v 200 n 50 m Up to 300 100 , 200 .
socket head plug) EY HA GB EH KC KH H GB GA HB G GA N N KW A Z + Stroke Adjustment bolt GD GC Model Standard stroke EB A EA EH ES EW EY G GA GB GC GD H HA HB HW CY1F10 49 10 16 7 6.5 16 27 9 7 19.5 14 6 28 26 14 35.5 50,100,150,200,250,300 CY1F15 52.5 10 16 7 6.5 16 29 9 8 23 17 9 34 32 17 41.5 50,100,150,200,250,300,350,400,450,500 CY1F25 70 13 17 10.5 8 22 40 10 12 33.5 22.5 12 46 44 23.5
5 15-17-5 6 Series AS-FPQ/FPG Dimensions H (width across flats) Applicable tubing O.D. d A L4 D1 L3 D2 M1 L1 L2 T M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max. Min. Max. 1 2 Min.
L L H Holding point Holding point H Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 40 20 80
(Tampa) 8507-H Benjamin Road Tampa, FL 33634 Tel: (813) 243-8350 FAX: (813) 243-8621 SMC Pneumatics Inc. (Houston) 9001 Jameel, Suite 180 Houston, TX 77040 Tel: (713) 460-0762 FAX: (713) 460-1510 SMC Pneumatics Inc. (Portland) 14107 N.E. Airport Way Portland, OR 97230 Tel: (503) 252-9299 FAX: (503) 252-9253 SMC Pneumatics Inc. (Cincinnati) 4598 Olympic Blvd.
.: 6, 8 K A Manual override (locking lever type) A M 300mm (lead wire length) I With indicator light/ surge voltage suppressor G G Manual override (locking lever type) Pressure gauge mounting bore 1/8 Port size Indicator light ON OFF OFF ON B B H H N P A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN SMC SMC Model Port
Name Material Remarks 1 Body Aluminum 2 Adapter plate Aluminum 3 Spool Special stainless steel 4 Sleeve Special stainless steel 5 Gasket H-NBR 6 Flange Aluminum 7 O-ring H-NBR 8 Spring pin Carbon steel 9 Bolt Carbon steel Not in 2 circuit model 10 Bolt Carbon steel 11 Retaining ring Carbon steel 12 Radial bearing Allowable leakage according to differential pressure 6000 MQR12 Port-to-port