Applicable model Rated current [A] Sensitivity of leak current [mA] Short circuit display method HRSH100--20-B 30 Earth leakage breaker HRSH150--20-B HRSH200--20-B 40 HRSH250--20-B 50 HRSH300--20-B 30 Mechanical button * 400 V type is equipped as standard.
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
Hs A B A B Proper Auto Switch Mounting Position (mm) D-A7H, A80H, A73C, A80C D-F7, F7V, F79F, J79 D-J79C, F7W, F7WV D-J79W, F7BAL, F7BAVL D-A7 D-A80 D-F7NTL D-A79W Bore size (mm) B B A A B A B A 32 3 11 51 43 6 46 5.5 45.5 40 5.5 13.5 49.5 57.5 8.5 52.5 8 52 50 19 11 53.5 61.5 14 56.5 13.5 56 63 22 14 59 67 17 62 16.5 61.5 Auto Switch Mounting Height (mm) D-A7H, A80H D-F7, J79, F7W D-J79W
A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.
Install the separately connected controller and high voltage power B : M4 thread B : M4 thread supply module by at location B using M4 screw (x 6). Refer to 6. Dimensions for details. B : M4 thread B : M4 thread .Adding a high voltage power supply module a. High voltage power supply module to be added should be Connected by D-sub connector at location C.
block (B) 1 Cross recessed round head screw 1 M38L 2 Holding block (A) 1 2 Holding block (A) 1 2 1 Switch block (A) 1 1 Switch block (B) 1 1 Holding block (A) 1 No.
-B 25 No.VQC1000V-OMM0001-B 26 No.VQC1000V-OMM0001-B 27 No.VQC1000V-OMM0001-B 28 No.VQC1000V-OMM0001-B 29 No.VQC1000V-OMM0001-B 30 No.VQC1000V-OMM0001-B When the valve is failing, use this flow chart to clarify the cause of the failure and take countermeasures appropriate for the cause.
AL-OMQ0006-C PRODUCT NAME LUBRICATOR MODEL / Series / Product Number AL10-M5(-2,3,6,R,Z)-A AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-A AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,3W,Z)-A AL40-(F,N)06(B)(-2,3,6,8,R,3W,Z)-A AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,3W,Z)-A AL60-(F,N)10(B)(-2,3,6,8,R,3W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3.
locking) Section B-B Section B-B Section A-A *Above figure show the unlocked state.
Formula for Obtaining the Set Value A B ZSP P_1 or P_3 P_2(H_1) or P_4(H_2) PSE200 PSE300 P_1(P_3)=A-(A-B)/4 P_2(P_4)=B+(A-B)/4 Hi Auto-shift input PS H_1(H_2)=(A-B)/2 Lo ISA B Switch output response time at time of auto-shift input A Auto-shift input time C Precision indicator setting PSE PSE200 PSE300 15 ms or less 10 ms or more This function eliminates slight differences in the output
Discharge port (FLUID OUT) Pump chamber B Pump chamber A Check valve Shaft Suction port (FLUID IN) Diaphragm B Diaphragm A Drive chamber A Drive chamber B Control unit 1.
(FLUID OUT) Pump chamber B Pump chamber A Check valve Shaft Suction port (FLUID IN) Diaphragm B Diaphragm A Drive chamber A Drive chamber B Control unit 1.
A B-1 A A-1 B B-2 B A-2 COM-A/COM B-3 COM-B/ A-3 Cable type Nil Robotic cable (Flexible cable) S Standard cable Cable color Connector D terminal no.
D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
When connecting wire, be careful because using lead wire that is outside of compatible lead wire ranges, or that are tightened to anything other than the proper torque, creates a risk of defective contact and other problems. -15No.SJ2000-OMM0001-B -16No.SJ2000-OMM0001-B -17No.SJ2000-OMM0001-B -18No.SJ2000-OMM0001-B -19No.SJ2000-OMM0001-B -20No.SJ2000-OMM0001-B -21No.SJ2000-OMM0001-B -22No.SJ2000
Without brake C section details Cross section BB l\rodel D F L 1 5 4 231 LXPB B-50 L X P B B . 7 5 173 256 52 L X P B _ B _ 1 0 0 204 281 246 323 LXPB B -.125 L X P B B 1 5 0 271 348 120 90 L X P B _ B _ 1 7 5 296 373 LXPB_B_-200 321 394 ?$rc zs S8[i8$ [10 Camraclnectl' 0i|llomiom $lift $crExi tlE LXPB S With brake I I shows the localion at which origin point swiich operates.
Series VS R8b S RUBBER SEAL/METAL SEAL SERIES VSR8/VSS8 2-position Single solenoid (FG-S) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Metal) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Rubber) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 3-position Closed center (FHG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Exhaust center (FJG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Pressure center (FIG-D) (A)(B) 4 2 5
Grommet: G Conduit: C (Q) Approx. 300 Approx. 280 Approx. 300 D D F Q F Q Width across flats H Class H coil Broken line section C C R G1/2 R E E A H A B B 2 x P Port size 2 x P Port size 2 x M, thread depth N 2 x M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6 to 12 F S Q 27.5 34 F (Q) 25 R C U C (44) R E R G1/2 E G1/2 A H D (S) B B A H D 2 x P Port size 2 x P Port size
BUSY OFF 27 No.SFOD-OMT0011CN-A 4.2 (1) a) View(V) 4.1 (1-1-2) View (V) Actuator selection b) b-1) conditions Model Motor mounting Lead Stroke 28 No.SFOD-OMT0011CN-A b-2) Search from Part No.