SMC Corporation of America
Elite Part Number Search
Search Results "25A-ZSE20B-Y-M-M5-WB"

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread)

Series: 25A-ISE20, Rated Pressure Range: CH (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specifications: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)]

Reducing type Reducing insert bushing 4 Series LQ1 Dimensions Male Connector: LQ1H-M Metric sizes M Connection threads R/NPT Model L H A M W E Applicable tubing O.D. 1/8 LQ1H11-M LQ1H12-M LQ1H21-M LQ1H22-M LQ1H23-M LQ1H24-M LQ1H31-M LQ1H32-M LQ1H33-M LQ1H34-M LQ1H35-M LQ1H36-M LQ1H41-M LQ1H42-M LQ1H43-M LQ1H44-M LQ1H51-M LQ1H52-M LQ1H53-M LQ1H54-M LQ1H61-M LQ1H62-M LQ1H63-M LQ1H64-M 4 3 6

Nil S n M L Auto switch type Bore size Nil Without auto switch (built-in magnet cylinder) 40mm 50mm 63mm 40 50 63 Refer to the table below for auto switch models. Locking direction Cylinder stroke (mm) Refer to the standard stroke table on page 3.

M G (Valve open) Q N R Pilot port 12(P1) Indicator (Option) 1 8 2 x (Back side 10(P2)) VNA P1 4 x P S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3

Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900

(Refer to the figure below.) 4) Remove the cable gland t and plain washer y and rubber seal u . 2. Wiring 1) Pass them through the cable i in the order of cable ground t, washer y, rubber seal u, and then insert into the housing r. 2) Dimensions of the cable i are the figure as below.

The ISE/ZSE20B, ISE/ZSE20C, ISE/ZSE40A, and ISE/ZSE80 series digital pressure switches feature an IP65 enclosure. The ISE/ZSE20B series (for air pressure) catalog can be found here.

Power supply/output connection lead wire ZS-40-W Lead wire length 2 m Sensor connector (e-con) ZS-28-C-5 1 pc. Lead wire with connector for copying ZS-40-Y Connect up to 10 slave units 10 LFE0 Series For the flow switch precautions, refer to the Operation Manual on the SMC website.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: Female Thread, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: w/o Operation Manual, w/o Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)