SMC Corporation of America
Elite Part Number Search
Search Results "AL40-04-38-A"

K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29

AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 No. Part no.

Rated voltage 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Model Port size (Rc 1/4) (Rc 3/8) (Rc 1/2) (Rc 3/4) (Rc 1) 02 03 04 06 10 2232 2232 2242 2352 2362 4 5 6 7 8 9 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC for inquiry.) Refer to the table (1) given below for availability. Refer to page 17-3-65 for ordering a coil only.

A A A A MAX.6 10.5 38 (GZ, GS: 38.7) [39.7] 22.6 (GZ, GS: 23.3) [24.3] 10.5 (Lead wire length) (Lead wire length) 4-Rc(PT)1 4 (P, R port) G: 300 4-Rc(PT)1/4 (P, R port) 18 P=17 (Pitch) G: 300 H: 600 L2 6.5 L1 (Non-locking) Manual override (Non-locking) Manual override Built-in speed controller 63[69.5] 50.6 A A 63 [69.5] 44 33 25 B B 50.6 A A 44 5.5 56.5 1 33 24.5 2n-One-touch fitting

Data View A-A Mounting dimensions Bore size (mm) Stroke range (mm) N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA A 20 25 32 40 50 75, 100, 125, 150, 200 25 38 80 60 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 32 46 95 70 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 75, 100 125, 150 200, 250 300 32 50 105 80 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 38 60 125 95

KQ2P-04 KQ2P-06 KQ2P-08 4 6 32 16 6 8 35 18 8 10 39 20.5 A A A B A B A FREE LOCK 1-3-11 12 Series SZ3000 Manifold Option DIN rail dimensions/Weight D-sub connector (25 pins)/Cable assembly AXT100-DS25015 030 050 VZ1000-11-1Refer to the L dimension tables Enter a number from the DIN rail dimension table below.

When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?

Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.

Use a watchmaker driver whose grip dia. is 5 to 6mm when tightening the auto switch mounting screw.

(L4) (L3) (5.25) L2 L1 Top entry port Not machined 27 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

(L4) (L3) (5.25) L2 Top entry port Not machined 27 L1 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

(L4) (L3) (5.25) L2 Top entry port Not machined 27 L1 P = 10.5 55 29 13 63.5 <67.5> 13 (12) Indicator light Manual override 4.5 66 (35) (5.5) A A A B A B A B A B A 93.5 <100.4> 40 4 x M5 mounting hole 67 66 2 Stations 8 7 6 5 4 3 2 1 D side U side n DIN rail clamp screw C8 [3(R) EXH port] C8: 8 One-touch fitting R R 61.5 G 1/2 18.7 7.7 40.7 25 9.3 B B B B B B B B X X P P A A A A A A A A

ANSI symbol shows the valve as a single inlel 4.way, bul valve may be used, withoul modilica. tion, as a dual inlet 4.way, a 3.way, or a 2-way, by piping and/or plugging lhe appropriate ports.

A ARX AMR ARM ARM ARP IR-A A-A X IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ Component Parts Replacement Parts Description No.

Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5

Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5

FKM Needle Needle guide Stainless steel 316 Stainless steel 316 Body B Stainless steel 316 3 Series ASG Dimensions ASG22F-M5 H L4 (Width across flats) Applicable tubing O.D. d A L6 D L5 M L3 L1 T L2 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 H (Width across flats) L4 Applicable tubing O.D. d L6 A D L5 M T L1 L3 L2 Max.

Model A L D KQ2P-04 KQ2P-06 KQ2P-08 4 6 32 16 6 8 35 18 8 10 39 20.5 A A A A A B B 5 Series SZ3000 DIN rail dimension table/weight table D-sub connector (25 pins)/cable assembly VZ1000-11-11 VVZS3000-21A~ 3 Refer to the L dimension table Enter a number from the DIN rail dimension table below in the .