Accuracy: Basic Type, Size: 32, Motor Mounting Position: D (In-line), Motor Type: NZ (Mounting Type Z), Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 150mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange)

Accuracy: Basic Type, Size: 63, Motor Mounting Position: D (In-line), Motor Type: NX (Mounting Type X), Lead Screw: C [LEY25, 3mm; LEY32, 4mm, (5); LEY63, 5mm], Stroke: 150mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: F (Rod Flange)

Accuracy: Basic Type, Size: 32, Bearing Type: M (Slide Bearing), Motor Mounting Position: Top Mounting, Motor Type: NT (Mounting Type T), Lead Screw: C [LEYG25, 3mm; LEYG32, 4mm, (5)], Stroke: 150mm, Guide Option: F (w/Grease Retaining Function)

Accuracy: Basic Type, Size: 25, Bearing Type: M (Slide Bearing), Motor Mounting Position: D (In-line), Motor Type: NZ (Mounting Type Z), Lead Screw: C [LEYG25, 3mm; LEYG32, 4mm, (5)], Stroke: 150mm, Guide Option: F (w/Grease Retaining Function)

Accuracy: Basic Type, Size: 32, Bearing Type: M (Slide Bearing), Motor Mounting Position: Top Mounting, Motor Type: NZ (Mounting Type Z), Lead Screw: B [LEYG25, 6mm; LEYG32, 8mm, (10)], Stroke: 150mm, Guide Option: F (w/Grease Retaining Function)

Accuracy: Basic Type, Size: 32, Bearing Type: M (Slide Bearing), Motor Mounting Position: Top Mounting, Motor Type: NZ (Mounting Type Z), Lead Screw: C [LEYG25, 3mm; LEYG32, 4mm, (5)], Stroke: 150mm, Guide Option: F (w/Grease Retaining Function)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without built-in magnet, Support bracket: Without auto switch mounting

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure