Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification:
Clean Series: 11 (Vacuum Suction Type), Magnet: D (Built-in Magnet), Mounting: F (Rod Side Flange Style), Bore Size: 40mm, Port Thread: Rc, Stroke: 300mm
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: Without
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 40mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Non-locking Style, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: Without
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Left Right 15 -60 -60 10 -40 -40 Air consumption -20 -20 5 S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U NL HL H S 1 S 2 R U NL HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE
ZF Left Right 15 -60 -60 ZP 10 -40 -40 Air consumption ZCU -20 -20 5 S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U NL HL H S 1 S 2 R U NL HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H S 1 S 2 R U N L HL H kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP a M O DE SET1 SET2 kP
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 40mm, Stroke: 300mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Without magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Without magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Without magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Without magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port