C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5
DD1629 Reed Auto Switch Direct Mounting Style D-A90(V)/D-A93(V)/D-A96(V) Refer to SMC website for the details of the products conforming to the international standards.
D D D D D CRA1 C C C CRQ2 MSQ MRQ C D D DKey 20(mm) Nominal size C D 50 63 80 100 19.5 39.5 21 45 23.5 53.5 30 65 Note) Dimensions and tolerance of the shaft and keyway are the same as the standard.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order 10 R E C L 25 150 M9BW C Number of auto switches Mounting Nil S n B L F G 2 pcs. 1 pc. n pcs.
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Built-in magnet D With auto switch Bore size (mm) 10 C D U 16 30 D M9B 21 C D U 16 30 D M9B Cylinder stroke (mm) Copper, fluorine and silicone-free + low particle generation Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. 21 22 Relief type Vacuum suction type Auto switch D-A93
H:Distance from the cylinder center axis to the mounting surface for the table L MXY H dimension (mm) MXH6 MXH10 MXH16 MXH20 MTS 24.5 30.5 34.5 41.5 Cylinder shaft center m Load center of gravity Selection Graph z to c (Vertical Mounting) Graph c c Maximum Speed 500 mm/s or Less Graph z z Maximum Speed 100 mm/s or Less 1 100 10 Mass m (kg) Mass m (kg) 20 0.1 16 20 16 1 10 10 6 6 0.01 0.1
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Stroke: 200mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Stroke: 175mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 40mm, Stroke: 175mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Mounting Bracket)
28 27 26 14 28 27 26 29 30 31 29 30 31 26 31 GR-S-010(10g 16 2025 75 2025 100 3263 100 17 17-3.
, Chamfered, Roller 0.74 0.80 0.86 Double acting with spring loaded REC 40 Model C 5 D 40 48 53 55 60 65 60 65 70 75 80 85 75 80 85 Mounting bolt M3 x 45l M3 x 55l M3 x 60l M5 x 55l M5 x 60l M5 x 65l M5 x 60l M5 x 65l M5 x 70l M5 x 75l M5 x 80l M5 x 85l M6 x 75l M6 x 80l M6 x 85l Lever with built-in shock absorber 0.97 1.01 1.05 RSQB12-10 RSQB16-10 -15 RSQB20-10 -15 -20 RSQB32-10 -15 -20
D Side support B MY-SB 2 x J 2 x H C D A B A B C D E F G H J Applicable cylinder MY1W16 MY1W20 MY1W25 MY1W32 MY1W40 MY1W50 MY1W63 Model MY-S16A 61 71.6 15 26 4.9 3 6.5 3.4 M4 x 0.7 B MY-S20A 67 79.6 25 38 6.4 4 8 4.5 M5 x 0.8 B MY-S25A 81 95 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 100 118 45 64 11.7 6 11 6.6 M8 x 1.25 B 120 142 MY-S40A M10 x 1.5 55 80 14.8 8.5 14 9 B 142 164 MY-S63A 172 202 M12
Colors indication Color Black Clear Blue White Symbol B C BU W Color Yellow Red Green Orange Symbol Y R G YR Colors other than Black are made to order only.
Use the appropriate pliers (C-type snap ring mounting tool) for installation and removal of the snap ring. 2. Take precautions even when using the appropriate pliers (C-type snap ring mounting tool). The snap ring may slip off the end of the pliers (C-type snap ring mounting tool) and spring out, causing bodily injury or damage to nearby equipment.
only. 2) Applicable to the D-M9 (V), D-M9W (V), and D-M9A (V) only. 3) Applicable to the D-B53/B54, D-C73(C)/C80C, D-A93(V), D-A73(C)/A80C, DA53/A54, D-Z73, and D-90/97/90A/93A only. 4) For reed auto switches M8 and M12 type with connector, please contact SMC. 5) The standard lead wire length of the trimmer auto switch is 3 m. 6) The standard lead wire length of the solid state auto
How to Order Standard B 20 30 D C CQSY B 20 30 D C F9BW S CDQSY With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
For installation and removal, use an appropriate pair of pliers (Tool for installing a type C snap ring). 2.
Description Body End cover A End cover C End cover B End cover D Cylinder tube No.