switch model D-A44 D-A44C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5/A6 D-F5W D-J59W D-F5BAL D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W D-A3/A3C D-A44/A44C D-G39/ G39C D-K39/K39C D-B5/B6 Bore size (mm) Bore size (mm) A B A B A B A B A B A B A B Hs Hs Hs Ht Hs Hs Ht Hs Hw Hs Hw 31 40 40 40 9.5 81 2 10.5 0 72.5 31 4 2 8.5 69 0 0.5 11.5 1.5 38 73 69 38.5 0 0 80.5 3.5 35 43.5
switch model D-A44 D-A44C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5/A6 D-F5W D-J59W D-F5BAL D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W D-A3/A3C D-A44/A44C D-G39/ G39C D-K39/K39C D-B5/B6 Bore size (mm) Bore size (mm) A B A B A B A B A B A B A B Hs Hs Hs Ht Hs Hs Ht Hs Hw Hs Hw 31 40 40 40 81 9.5 2 10.5 0 72.5 31 4 8.5 2 69 0 0.5 11.5 1.5 38 73 69 38.5 0 0 80.5 3.5 35 43.5
Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-12HC1Power supply: 200/220(V)AC 10% Compatible
position 2.6 LC3F2 D-M9NAV/D-M9PAV D-M9BAV 500(1000)(3000)(5000) Mounting screw M2.5 x 4 L Stainless steel Indicator light Slotted set screw (flat point) Indicator light Slotted set screw M2.5 x 4 L 8 2 8 3.2 4.6 2 4.6 2.6 SMC SMC 4 2.8 2.8 2.7 22 22 2.6 2.6 2.6 9.3 9.3 4 4 6 Most sensitive position 6 Most sensitive position 507 A
Auto Switch Proper Mounting Height (Standard type) [mm] Auto switch model D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-F5NT D-Y59l D-Y7P D-Y7lW D-Y7BA D-Z7l D-Z80 D-M9l D-M9lW D-M9lA D-A9l D-A9lV D-M9lV D-M9lWV D-M9lAV D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-G39 D-K39 D-A3l D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23
The auto switch may be damaged if a screw other than the one supplied is used. 25ALEC Weight (g) LEC S LEC SS-T D-M9P(V) D-M9B(V) D-M9N(V) Auto switch model 0.5 m (Nil) 8 7 LEC Y 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 Motorless 5 m (Z) 68 63 LAT Dimensions LZ (mm) D-M9 D-M9V LC3F2 Mounting screw M2.5 x 4 L Slotted set screw (flat point) 500 (1000) (3000) (5000) Indicator light 2.6 3.95
(kg) Applicable dryer Port size NPT A B C D E D E Part no.
0 28 1.5 31 CS1 80 2.5 28 6 21.5 14 29.5 9 24.5 6.5 22 2.5 28 5.5 31 100 2.5 28 6 31.5 14 39.5 9 34.5 6.5 32 2.2 28 5.5 31 C76 C85 Auto Switch Mounting Height C95 D-F5, D-J5 D-F5W, D-J59W D-F5BAL, D-F5NTL D-F59F D-A3, D-K39 D-G39 D-A44 D-Z7, D-Z80 D-Y59, Y7P D-Y7W D-A5 D-A6 D-A59W D-Y69, D-Y7PV D-Y7WV D-Y7BAL D-P5DWL Bore size (mm) CP95 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht NCM
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 200mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 65, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No