/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B

A A A A IN OUT IN OUT Bracket L3 L2 L1 L4 L1 K S T V KS KT KV KST L3 43 57 57 75 80 96 Attachment Model L2 43 57 57 75 L1 41.5 55 55 72.5 77.5 93 L1 41.5 55 55 72.5 L2 61 76 76 99 L2 43 57 57 75 80 96 L1 41.5 55 55 72.5 L2 43 57 57 75 L3 43 57 57 75 L1 41.5 55 55 72.5 L3 43 57 57 75 L1 41.5 55 55 72.5 77.5 93 98 98 L2 43 57 57 75 80 96 96 101 L1 28 41.5 55 55 72.5 77.5

75 75 75 75 75 136 144 152 152 164 164 41 23 51 25 51 25 56 29 61 29 Standard Type/with Mounting Brackets Dimensions not shown are the same as the basic type (drawing above).

Stations . 3 2 1 Blanking plate assembly Connector box mounting position D side SX3000-75-1A(-Q) Symbol Mounting position U U side D D D side SS5Y3-45-AU-05D-C6 1 set (Type 45, 5-station manifold base part no.) SX3000-75-1A 1 set (Blanking plate assembly part no.) SY3140-5LOU 2 sets (Single solenoid part no.) SY3240-5LOU 2 sets (Double solenoid part no.)

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

75 75 75 75 75 136 144 152 152 164 164 41 23 51 25 51 25 56 29 61 29 Standard Type: With Mounting Bracket Dimensions not shown are the same as basic style.

75 75 75 75 75 136 144 152 152 164 164 41 23 51 25 51 25 56 29 61 29 Standard Type: With Mounting Bracket Dimensions not shown are the same as basic style.

Auto Switch Mounting Height (mm) D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G5BA D-G59F Auto switch model D-F5 D-J59 D-F5W D-J59W D-F5BA D-F59F D-F5NT D-Z7 D-Z80 D-Y59 D-Y7P D-Y7BA D-Y7W D-A9 D-M9 D-M9W D-M9A D-A3C D-G39C D-K39C D-A44C D-A9V D-M9V D-M9WV D-M9AV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size (mm) Ht Hs 40 50 63 80 100 Hw Hs Ht Hs Ht Hs Ht Hs

D D Note) Be sure to use a flat washer for the A type mounting. b) B type mounting (when using the cylinder tube threads) E t E t Compatible mounting bolt dimensions Model A type mounting B type mounting C (mm) D: Bolt length (mm) Mounting bolt size E (mm) Mounting bolt size MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D M4 x 0.7 35 + Stroke

(g) Stroke (mm) Model 15 10 5 C(D)U6-S,T C(D)U10-S,T C(D)U16-S,T C(D)U20-S,T C(D)U25-S,T C(D)U32-S,T 28(38) 25(35) 22(27) 48(58) 40(50) 36(41) 71(101) 56(86) 50(75) 133(170) 106(143) 95(128) 235(294) 193(252) 176(230) 347(425) 286(364) 262(335) For the weight of auto switch, refer to page 68 to 72.

B C D A Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.

Same side 75 90 120 (n 4) 2 120 + 50 (n 2) 2 90 + 50 (n 4) 2 20 + 50 Different sides D-B59W n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 2, 3, 4 90 + 50 (n 2) n = 2, 4, 6 120 + 5 (n 2) 75 + 50 (n 2) Same side n = 2, 4, 6, 8 120 90 1 pc. 15 35 80 90 Different sides 75 100 Same side 35 + 30 (n 2) 75 + 30 (n 2) 80 + 30 (n 2) 90 + 30 (n 2) D-A3 D-G39 D-K39 Different

D Dimensions Dimensions (mm) (mm) Model B A C D E F G H I J Y Model B A C D E F G H I J Y ZPX40HBJ25-B01-A18 ZPX63HBJ25-B01-A18 109 160 120 171 50-B01-A18 50-B01-A18 40 41.4 28.4 43.2 20.5 32 47 69 144 195 13 63 65.1 45.5 67.6 31.5 43 58 80 155 206 21.5 75-B01-A18 75-B01-A18 180 231 191 242 ZPX50HBJ25-B01-A18 ZPX80HBJ25-B01-A18 112.5 163.5 125.5 176.5 50-B01-A18 50-B01-A18 50 51.9 35.7 54

) With dew point indicator 1 10/2.5 3 25/6 50/12 100/25 200/50 300/75 500/125 600/125 750/150 1000/190 5 S Standard equipment 10 20 30 50 60 75 100 Note) In case of two or more options, indicate them in alphabetical order.

Purge air flow rate (l/min(ANR))(3) 2.5 12 25 50 75 125 125 150 190 6 Inlet air pressure (MPa) 0.7 Part no.

Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A5/A6 D-F5(W)/J59(W)/F5BA D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-Z7/Z80 Hs Hs A A Ht Ht Ht Ht B B Auto Switch Mounting Height Auto Switch Proper Mounting Position D-F5/J59 D-F5W/J59W D-F59F D-F5BA D-F5/J59 D-F5W/J59W D-F59F/F5BA D-F5NT D-A59W D-F5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-M9V/M9WV D-M9A V D-A5/A6

8 10 12 7.5 9 4 4 5 15 Data Hs D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-F7V D-F7WV D-J79C/A72 D-F7BAL D-F79F 5 16 20 25 8 10 12 8 9.5 2 2 3 (mm) C85 Auto Switch Mounting Height D-A7 D-A80 D-A7H/A80H D-F7/J79 D-F7W/J79W D-F7BAL D-F79F D-F7V D-F7WV D-F7BAVL D-C7/C80 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-A73C D-A80C D-H7C D-A79W D-J79C D-H7 D-H7C D-H7W D-H7BAL D-H7NF Bore 3 16 Hs Hs

Mounting bolt C D Mounting bolt Mounting bolt D 65 70 75 85 95 120 145 85 95 105 130 155 90 100 110 135 160 105 115 140 165 120 130 155 180 Model C D 50 55 60 65 75 85 55 60 65 70 80 90 60 65 70 80 90 115 140 Model C R(D)QB20-15 -20 -25 -30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 R(D)QB63