SMC Corporation of America
Elite Part Number Search
Search Results "CXSJL25-40-M9PV"

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port

Bearing Style: L (Ball Bush Bearing), Bore Size: 25mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 100mm

Bearing Style: L (Ball Bush Bearing), Bore Size: 25mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 10mm

Bearing Style: L (Ball Bush Bearing), Bore Size: 25mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 75mm

Bearing Style: L (Ball Bush Bearing), Bore Size: 25mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 50mm

Bearing Style: L (Ball Bush Bearing), Bore Size: 25mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 20mm

Bearing Style: L (Ball Bush Bearing), Bore Size: 25mm, Port Thread: Bore 6-25: M Thread; Bore 32: Rc, Piping: Standard Porting, Stroke: 30mm

A Graph 1 Graph 2 120 60 110 B 100 50 C P1 63 63 90 80 40 70 Regulator Circuit C Load weight (kg) Load weight (kg) P2 60 30 50 50 A 50 Regulator valve 40 20 40 40 30 B 32 32 20 10 C P1 10 0 0 0.4 0.3 0.3 0.5 0.6 0.7 Operating pressure (MPa) 0.4 0.5 0.6 0.7 Operating pressure (MPa) Selection example Confirmation of allowable kinetic energy Selection conditions: Transfer direction: Vertical

Eccentricity 200 mm 1 10 10 0.1 Weight m (kg) Weight m (kg) Weight m (kg) 1 1 20 16 20 16 10 6 20 16 10 6 0.01 0.1 0.1 10 6 0.01 0.001 0.01 80 100 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 Overhang L (mm) Overhang L (mm) Overhang L (mm) Selection Example 1.

10 6 0.01 0.1 0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L (mm) Overhang L (mm) Overhang L (mm) Graph b b Load Eccentricity 100 mm Graph , Load Eccentricity 100 mm Graph 1 Load Eccentricity 100 mm 1 10 10 Mass m (kg) Mass m (kg) Mass m (kg) 1 20 16 20 16 20 16 10 6 0.1 1 10 0.1 10 6 6 0.01 0 20 40 60 80 100 0.01 0.1 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L

32 mm 40 40 mm 45 45 mm 50 50 mm 56 56 mm 63 63 mm 67 67 mm 80 80 mm 85 85 mm 100 100 mm For applicable auto switches, refer to the table below.

) 28 VDC or less LEY Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less LES 100 A or less at 24 VDC Leakage current 0.8 mA or less Indicator light Red LED illuminates when turned ON.

60 15 0.4 0.3 150 0.4 0.4 MHK 40 10 0.3 0.3 100 0.2 0.2 0.2 MHS 5 20 50 MHC 0 0 40 Gripping point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHT MHW2-25D MHW2-40D 160 50 MHY Pressure 0.7 MPa Pressure 0.7 MPa 140 0.6 0.6 40 Gripping force (N) Gripping force (N) 120 MHW 0.5 0.5 100 30 0.4 0.4 80 MRHQ 0.3 0.3 20 60 0.2 0.2 Misc. 40 10

60 15 0.4 0.3 150 0.4 0.4 MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 40 10 0.3 0.3 100 0.2 0.2 0.2 MHS 5 20 50 MHC 0 0 40 Gripping point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHT MHW2-25D MHW2

Hmm 0.3MPa 0.7MPa 0.3MPa 60 0.7MPa 0.4MPa 60 0.4MPa 40 40 20 20 100 80 60 40 20 0 100 0 80 60 40 20 Gripping point L mm Gripping point L mm 12-3-6 7 Model Selection Series MHF2 Confirmation of External Force on Fingers: Series MHF2 Step 3 MHZ L L MHF MHL Mr Mp Fv My MHR MHK MHS L MHC MHT MHY L: Distance to the point at which the load is applied (mm) MHW Maximum allowable moment Allowable

60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-16D MHF2-20D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang Hmm 0.3MPa 0.7MPa 0.3MPa 60 0.7MPa 0.4MPa 60 0.4MPa 40 40 20 20 100 80 60 40 20 0 100 80 60 40 20 0 Gripping point L mm Gripping point L mm 12-3-6 7 Model Selection Series MHF2 Confirmation of External Force on Fingers

mm 40 L = 240 mm L = 200 mm L = 160 mm L = 120 mm L = 80 mm L = 180 mm L = 140 mm L = 100 mm L = 60 mm 30 50 20 10 Workpiece weight (kg) Workpiece weight (kg) Workpiece weight (kg) 5 10 10 5 5 1 1 1 0.5 5 40 30 20 10 5 40 30 20 10 5 40 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) Transfer speed V (m/min) 10-11-6 6 Series MIW/MIS Escapements Model Selection Allowable lateral

point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK 0 20 40 60 Gripping point L (mm) 100 80 80 100 120 140 160 0 20 40 60 Gripping point L (mm)

) Workpiece weight (kg) Workpiece weight (kg) 5 10 10 5 5 1 1 1 0.5 5 40 30 20 10 5 40 30 20 10 5 40 30 20 10 Transfer speed V (m/min) Transfer speed V (m/min) Transfer speed V (m/min) 10-11-6 6 Series MIW/MIS Escapements Model Selection Allowable lateral load MIW8 MIS8 MIW12 MIS12 0.7 MPa 70 0.7 MPa 30 0.6 MPa RE A B 0.6 MPa 0.5 MPa 60 REC 0.4 MPa 0.5 MPa 0.3 MPa 0.4 MPa Lateral load F (