SMC Corporation of America
Elite Part Number Search
Search Results "CY3RG40-700-Z73L"

Magnet: Built-in, Mounting: Center Trunnion, Tube Material: Aluminum Tube ø125~ø160, Steel Tube ø180~ø300, Bore Size: 125mm, Port Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 32mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Bore Size: 25mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Bore Size: 50mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Centralized Piping, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Bore Size: 40mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Centralized Piping, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Bore Size: 32mm, Port Thread: NPT, Piping: Centralized Piping, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Bore Size: 63mm, Port Thread: NPT, Piping: Standard, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Guide Type: Slide Bearing, Seal: None, Bore Size: 50mm, Port Thread: NPT, Piping: Standard, Stroke: 700mm, Adjuster: w/o Adjustment Unit, Suffix: Both Sides, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m Lead Wire, Number: -, Made to Order: -

Bore Size: 32mm, Port Thread: NPT, Stroke: 700mm, Switch Rail: Switch Rail, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting: Front Flange, Tube Material: Aluminum Tube, Bore Size: 125mm, Thread Type: Rc, Stroke: 700mm, Option: Cushions at Both Ends, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Bore Size: 40mm, Port Thread: NPT, Piping: Standard, Stroke: 700mm, Stroke Adjusting Unit: w/o Adjustment Unit, End Lock: None, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: Long Stroke

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Piping: G (Centralized Piping), Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 300mm

Piping: G (Centralized Piping), Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 900mm

Piping: G (Centralized Piping), Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 350mm

Piping: G (Centralized Piping), Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 800mm

Piping: G (Centralized Piping), Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 1500mm