FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 1.01963 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT, BTM PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 1.10231 lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VKF334, BASE MT, SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .16534 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT, SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .26054 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .29394 lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .40417 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, VV3K* BASE MT 1/8, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 0.40417 lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .55115 lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VKF334, BASE MT,SLIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 1.37788 lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 0.5732 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .57320 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, .62657 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, VV3K* BASE MT 1/8, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 0.6556 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT, SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 0.17636 lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, MFLD, VFK334, BASE MT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 0.66138 lb
, Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type?, MFLD, VKF334, BASE MT,SIDE PT, VALVE, VV3K* MANIFOLD VK 3-PORT, NJ, VV3K* BASE MT 1/8, 1.10231 lb
(Pages 10, 12, 15, 17) L-Tees Combine an elbow with a Tee. Mixed sizes of barbed branches are available. (Pages 9, 11, 15, 17) V-Tees orient the barbed branches on adjacent hex surfaces. Mixed branch sizes are available. (Pages 10, 12, 15) 1/8 NPT Male manifolds Hundreds of combinations for the OEM needing a fitting that requires a minimum amount of labor to install.
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Remote modeOpen A The time of FLT alarmClose FLT Operation stop FLT alarm status signal B The time of FLT alarmOpen A The time of WRN alarmClose WRN Continuing operation WRN alarm status signal B The time of WRN alarmOpen ALM Alarm status signal A The time of alarmClose B The time of alarmOpen RDY TEMP READY signal A TEMP READY statusClose B TEMP READY statusOpen A EnabledClose FREZ Anti-freezing