SMC Corporation of America
Elite Part Number Search
Search Results "HRS150-AN-40-A"

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: JM (w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping)

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: Applicable to DI Water Piping, High Pressure Pump: Inverter Pump Mounted, Feet: -, Flow Sensor: -

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: Inverter Pump Mounted, Feet: -, Flow Sensor: -

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: High Pressure Inverter Pump Mounted, Feet: -, Flow Sensor: -

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: Inverter Pump Mounted, Feet: None, Flow Sensor: without Either a Flow Sensor or Retaining Clip

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: Inverter Pump Mounted, Feet: with Feet/Without Rack Mounting Brackets, Flow Sensor: -

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: w/Electric Conductivity Control Function, Applicable to DI Water Piping, High Pressure Pump: Inverter Pump Mounted, Feet: -, Flow Sensor: -

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: w/Electric Conductivity Control Function, Applicable to DI Water Piping, High Pressure Pump: High Pressure Inverter Pump Mounted, Feet: -, Flow Sensor: -

Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)

Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: None, Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)

Rack Mount Refrigeration Chiller. O72. 74.00000 lb. CHILLER, RACK MOUNT, REFRIGERATION TYPE.

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets), Flow Sensor: Z1 (without Either a Flow Sensor or Retaining Clip)

Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], DI Water Piping: None, High Pressure Pump: T2 (High Pressure Inverter Pump Mounted), Feet: Y (with Feet/Without Rack Mounting Brackets)

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.