LED display Circuit OUT (+) Brown (Red) OUT (+) Brown (Red) Load + A 30 + Main circuit of switch Main circuit of switch 12 to 24 VDC 12 to 24 VDC A Applicable One-touch fittings Load KQ H L T 06-M5 16 OUT () Blue (Black) S Y OUT () Blue (Black) Other Series KQ/KS 13 Series KJ 14.5 6 reducer Example of connection with a PLC (Sequence controller) Series KJ (-X20) 16 PNP Sink type Input unit
Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only
Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ROTARY ACTUATOR, ACTUATOR, CRB1BW ROTARY ACTUATOR, KS, 30MM CRB1BW SINGLE-ACTING, .94614 lb
However, unlike KS and KX series rotary One-touch fittings, they do not rotate with low friction. Do not use the product in a manner in which the connected tube swings or rotates with respect to the fitting.
As tubing and fittings generally come as a set, be sure to check the operating pressure range of the fitting as well before use.
(See below. )
KF series: -101.3 kPa to 1 MPa
KQ2, KQG2, KQB2, KP, KS, and KX series: -100 kPa to 1 MPa
Z□ series vacuum ejector: -80 kPa to -91 kPa
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ROTARY ACTUATOR, ACTUATOR, CRB1BW ROTARY ACTUATOR, KS, 30MM CRB1BW SINGLE-ACTING, .66138 lb
A large digital display provides a clear view of the current and set values.
Cooling Capacity: 100 (11.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: MT (M + T)
Cooling Capacity: 100 (11.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKMT (A + K + M + T)
Cooling Capacity: 100 (11.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: KMT (K + M + T)
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + B1 + K
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + B + K
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K + S
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + S
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: w/Earth Leakage Braker w/Handle
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: B1 + K
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: w/Fluid Fill Port
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: Conforming to CE/UL Standards
Cooling Capacity: 10.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K