Bracket mounting inserts found on the standard ISE20 are omitted as well. 25A-ISE20 is UL/CSA, CE and RoHS compliant with an IP40 enclosure rating.
Cable length (L) A1 (17.7) (10.2) 1 2 5 6 (14) (18) 1 3 5 8 A B C 1.5 m 3 m 5 m 8 m A6 B1 B3 A1 A3 B6 (13.5) 1 2 5.7 15 16 Connector B Connector D (30.7) L (11) (14.7) (10) 10 m LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) 8 A B C 15 m Actuator side Controller side 20 m 5.5 6.3 5.7 (14.2) Connector C (Terminal no.)
NDH10 A1 MM NX R1 U1 d m t L1 L bore size bore size MQQ M I-J010B I-J016B IY-J010 IY-J015 10 16 10 16 Type C 3.2 3 12.2 1.7 0.3 3.3 + 0.048 0 3.3 0.030 0.060 16.2 8 21 M4 x 0.7 3.1 8 9 4.8 12.2 1.5 0.7 0.030 0.060 5 Type C 5 16.6 + 0.048 0 5 8 25 M5 x 0.8 6.4 12 14 RHC Double Knuckle Joint Mounting Nut Rod End Nut MK(2) Knuckle pin and set ring are shipped together.
across flats B1 M5 x 0.8 RE A B REC 16 [17] S + Stroke H + Stroke Z + 2 x Stroke Rod End Nut CX Bore size (mm) 10 16 H1 B1 CY 7 3.2 8 4 MQQ M [ ]: Denotes the values of AC.
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) Note 7) A reference value for correcting an error in reciprocal operation. Note 8) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw.
Thread type AS-D Port size Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT M5 U10/32 01 02 M5 x 0.8 AS-T 10-32 UNF 1/8 N ASP 1/4 ASN Made to Order AQ ASV Lubricant: Vaseline X12 Grease-free (Seal: Fluorine Coated) + Throttle Valve (Without Check Valve) X21 AK Ex.) AS1201FM-M5-23-X12 Ex.)
SVRE OFF [BK RLS]DC24V [BK RLS] [BK RLS]DC24V [BK RLS] EMG /LEC 58 - 15. 15.1. / 15.2 ON 59 - 5 () 60 - 15.3 50mm 15.4 ( ) 61 - 15.5 15.6 D 100 15.7 62 - 16. , , (), 16.1 /P.16 4. LED() /P.18 5.CN1: PLC /P.24 6.3 CN1 CN5 DC24V /P.16 4. /P.27 6.4 I/O /P.48 12. ONOFF /P.11 3. /P.48 12. CN1 CN5 DC24V /P.16 4. /P.27 6.4 I/O /P.14 3.4 63 - /P.28 7. (CN1:EMG ) /P.11 3.
LED() /P.18 5.CN1: PLC /P.24 6.3 / / CN1 CN5 / DC24V /P.16 4. /P.27 6.4 I/O /P.48 12. ONOFF /P.11 3. /P.48 12. / CN1 CN5 / DC24V /P.16 4. /P.27 6.4 I/O /P.14 3.4 63 - /P.28 7. (CN1: /P.11 3. EMG ) SV1.00 INP ON INP OFF (INP PLC ) /P.24 6.3 / /P.11 3.
Connector type A B D M8-3 pins M8-4 pins M12-4 pins CJP Lead wire length S 0.5 (m)(1.64 ft) CJ2 M 1.0 (m)(3.28 ft) Auto Switch Mounting Bracket Part No.
Note) Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z CS1 C76 C85 C95 CP95 NCM NCA D-X 20Data 6-15-7 7 Series NCA1 Basic Style: NCA1B (MX0 mounting style) ZB + Stroke P + Stroke D across flats 4-DD 2-EE (NPTF) AA KK EA MM BA B A C R WF G J E LF + Stroke Bore size (in) MM KK A AA B BA C D DD E EA EE G J R WF Y LF P ZB 150 (1.5") 5/8 7/16-20 3/
Refer to "9.3 Basic Parameter Setup (P. 43) " for details. Sensor resolution LAT3---30 m LAT3M---5m LAT3F---1.25 m PP+,PPNP+,NPNote) A Pulse input signal should be input earliest after 10 ms or more after changing the IN0, IN1 setting.
L2 L3 M D2 D2 L1 L1 L4 L4 H (Hexagon width across flats) H (Hexagon width across flats) D3 D3 L5 A1 A2 L5 A1 A2 D1 D1 T T Metric Size L4 L5 A1 A2 M Max.
L A T C A N X 1 5 2 Made to Order Note3) Card Motor controller Note2) NIL Standard product X152 I/O cable (without shield) Option Parallel I/O NIL Direct mounting N NPN D Note1) DIN rail mounting P PNP I/O cable length Note3) NIL Without cable 1 1 m 3 3 m 5 5 m Note 1) The DIN rail is not included, this must be ordered separately.
Code D33 SST Sensor Dual Module Code D44 Namur Sensor Dual Module Code I02 P+F NJ2-12GK-SN Code I09 P+F NCB2-12GM35-N0 Code I32 Omron E2E-X2Y1 Code I41 P+F NJ4-12GK-SN Code I45 P+F NJ3-18GK-S1N Code I56 IFC 2002-ARKG/UP Code K05 Omron D2VW-5 Code K06 Omron D2VW-01 Code B06 Omron D2VW-01 (ND9100F/P, ND9200F/P and ND9300F/P only) 2.5 Recycling and disposal WARNING (ND9000, ND7000): During automatic
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
.: ZS-46-A1) Bracket B (Part No.: ZS-46-A2) F0 Function setting F1 Function setting F99 Function setting : Some products do not have all the functions. If no function is available or selected due to configuration of other functions, [-] is displayed on the sub display (right).
MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Units specification Pressure range Default setting ISE20B: 0.050 MPa/ZSE20B: 5.0 kPa/ ZSE20BF: 5.0 kPa Hysteresis ISE20B MPa "Nil" or M ZSE20B(F) kPa Delay time 0.00 sec.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)