SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-M5-LD"

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Basic weight 0.74 P Additional weight 0.11/50 stroke P Cylinder stroke 100 stroke P Locking weight 0.08 (Locking at head end, manual release non-locking style) 0.74+0.11X100/50+0.08=1.04kg All mounting bracket 0.11 0.16 0.26 0.27 0.42 0.56 Additional weight per 50 stroke Single knuckle 0.15 0.23 0.26 0.26 0.60 0.83 Accessories Double knuckle (with pin) 0.22 0.37 0.43 0.43 0.87 1.27 1.7-

Specifications Model ISE35 Rated pressure range 0 to 1 MPa Display/setting pressure range 0.1 to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Series: 25A-ISE20, Rated Pressure Range: CH (-0.1 to 2 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specifications: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)]

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available

Pressure sensing for air and liquid non-corrosive to 630 and 304 SST; Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc with M5 female; Panel mounting adapter available

Suitable for the secondary battery manufacturing environment; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; 2 switch output (NPN or PNP), plus 1 analog output (V or MA); Port size: M5 female; Panel mounting adapter available