This is a legacy product, and replaced byASN2-N01-S
NORWAY SMC Pneumatics Norway A/S RUSSIA SMC Fluid Application GmbH SLOVAKIA SMC Slovakia s.r.o. SLOVENIA SMC Slovenia d.o.c. SPAIN/PORTUGAL SMC Espaa, S.A. OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd. Revised Content Edition B Series IR1000 and IR3000 added to Series IR2000. Air operated type IR2120 added to Series IR2000.
Model no. of NPT thread is AN101N01 and AN110-N01. Note 2) It indicates the inlet pressure for solenoid valve. Note 3) It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing. VEX Refer to page 5-10-13 for Precautions on these products.
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A4 (Bracket D for M12 Connector Type), Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 connector type), Bracket: A4 (Bracket D for M12 Connector Type)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Pad Diameter: ø63, Pad Type: HB (Heavy-duty, Bellows), Pad Material: S (Silicone Rubber), Buffer Body Material: J (Aluminum Alloy), Buffer Stroke: 75mm, Vacuum Inlet Thread Size: N01 (NPT1/8), Mounting Thread Size: A18 (M18 X 1.5)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: P (PNP open collector 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm), Set Value: P (Normal Output), OUT1 Set Value: 007 (0.7 MPa, −70 kPa, 70 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate
Body Size: 2 (1/8, 1/4 Basis), Style: 3 (Universal), Control Method: 1 (Meter-in), Port Size: N01 (1/8 NPT), Applicable Tube OD: 09 (5/16"), Sealant: S (Sealant)
Body Size: 2 (1/8, 1/4 Basis), Style: 3 (Universal), Control Method: 0 (Meter-out), Port Size: N01 (1/8 NPT), Applicable Tube OD: 01 (1/8"), Sealant: S (Sealant)