This is a legacy product, and replaced byZK2B15R5CLA-07-BK VACUUM EJECTOR. Vacuum Ejector. 99 lb. M18.
Port size 02 R1/4 N02 NPT1/4 F02 G1/4 Suffix for actuator* S Hard steel roller R Red Color of push button, selector B Black G Green Y Yellow Construction Non-actuated Actuated Force e u w R port 3 port only Port 2 Port 2 Port 1 Port 1 q t y r Component Parts No.
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
SRH VBA20A-03 VBA20A-F03 VBA10A-02 VBA10A-F02 VBA11A-02 VBA11A-F02 G27-20-01 AN20-02 ANA1-02 KT-VBA10A-18 VBA40A-04 VBA40A-F04 VBA22A-03 VBA22A-F03 VBA42A-04 VBA42A-F04 VBA43A-04 VBA43A-F04 Model Description Pressure gauge Silencer High-noise reduction silencer Elbow for silencer SRP G N S L G36-10-01 AN30-03 ANA1-03 KT-VBA22A-7 AN30-03 ANA1-03 G36-10-01 AN40-04 ANA1-04 G27-20-01 AN40-
N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE78G (0 to 16 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE78G (0 to 16 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE77G (0 to 10 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70G (0 to 1 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70G (0 to 1 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only)
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: 0 to 10 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -