Pressure Range: 0 to 2 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 50 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 16 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1.6 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Type: Pressure Switch, Fluid Type: Air, Maximum Pressure Rating: 1MPa, Minimum Pressure Rating: 0kPa, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [G] G, Plumbing Thread Nominal: [1/4] 1/4, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Humidity
-550(5) SUS630()SUS304() () / -7No.PS-OMU0008CN-D * 1015 10 1 2466 LCD * -8No.PS-OMU0008CN-D ISE20C X M 2 3 ISE20C -0.100~1.000 MPa Y ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02
Cable Specifications Piping Specifications and Weights Conductor area 0.15 mm2 (AWG26) Model 02 N02 F02 C01 A2 B2 Port size R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 Insulator O.D. 1.0 mm Color Brown, Blue, Black, White, Gray (5-core) Sheath Finished O.D. 3.5 Materials of parts in contact with fluid Pressure sensor: Stainless steel 630, Fitting: Stainless steel 304 Weight Body (Rear ported) 51
N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: F01 (Screw-in G1/8), VAC: F02 (Screw-in G1/4), EXH: F02 (Screw-in G1/4)
SRH VBA20A-03 VBA20A-F03 VBA10A-02 VBA10A-F02 VBA11A-02 VBA11A-F02 G27-20-01 AN20-02 ANA1-02 KT-VBA10A-18 VBA40A-04 VBA40A-F04 VBA22A-03 VBA22A-F03 VBA42A-04 VBA42A-F04 VBA43A-04 VBA43A-F04 Model Description Pressure gauge Silencer High-noise reduction silencer Elbow for silencer SRP G N S L G36-10-01 AN30-03 ANA1-03 KT-VBA22A-7 AN30-03 ANA1-03 G36-10-01 AN40-04 ANA1-04 G27-20-01 AN40-
Port size 02 R1/4 N02 NPT1/4 F02 G1/4 Suffix for actuator* S Hard steel roller R Red Color of push button, selector B Black G Green Y Yellow Construction Non-actuated Actuated Force e u w R port 3 port only Port 2 Port 2 Port 1 Port 1 q t y r Component Parts No.
HIGH PRECISION DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE50-80, 845, 181 lb
Pressure Range: ISE70G (0 to 1 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70G (0 to 1 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: M (SI Unit Only)
Pressure Range: ISE76G (0 to 5 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: Y (None)