Standard Strokes: Hydraulic Fluid Compatibility Hydraulic fluid Compatibility Standard strokes (mm) Long stroke Bore size (mm) 20 25 32 40 Standard mineral hydraulic fluid Compatible 25 to 300 W/O hydraulic fluids Compatible 25 to 400 800 O/W hydraulic fluids Compatible 25 to 500 Water/Glycol hydraulic fluids Phosphate hydraulic fluids Not compatible Standard strokes above have a minimal

401 to 500 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 Bore 20 68 81 93 106 131 156 12.5 25 37.5 50 75 100 48 61 73 86 111 136 36 18.2 25 72 85 97 110 135 160 185 12.5 25 37.5 50 75 100 125 52 65 77 90 115 140 165 36 18.2 32 72 85 97 110 135 160 185 12.5 25 37.5 50 75 100 125 52 65 77 90 115 140 165

100, 200, 300, 400, 500, 600 200, 300, 400, 500, 600, 700, 800 Specifications Operating pressure 0 to 0.7MPa Proof pressure 1.05MPa Ambient and fluid temperature 5 to 50C Fluid Turbine oil (40 to 100cSt) Converter standard effective oil level stroke/effective volume (cm3) Nominal size (mm) Limited flow* (l/min) Standard effective oil level stroke (mm) 100 200 300 400 500 600 700 800 50 63

15 1600 30 30 15 1600 kg mm/s mm 2000 250 500 1000 250 500 (1475) 1000 0.05 When axes are combined, select each axis considering the weight of the work piece and the body. 100 200 300 400 500 600 700 800 Stroke mm 900 1000 Z axis specifications 200 5 10 W mm Motor Ball screw lead Guide Maximum work load Maximum speed Repeatability 400 5 10 20 32 20 32 High rigidity direct acting guide 7.5

W Axial Right F R L T B Cable length Left Top 2m 3m 4m 5m 2 3 4 5 Motor specification Standard motor Matsushita Electric Industrial Co., Ltd.

Count Pressure Characteristics Flow Characteristics Supply pressure: 0.6 MPa Set pressure: 0.25 MPa 600 1 500 kPa 500 Output deviation factor (% F.S.) 0.5 Set pressure (kPa) 400 kPa 400 Out 300 kPa 300 0 Return 200 kPa 200 0.5 100 kPa 100 50 kPa 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 2 1 3 4 5 6 0 7 1.0 Supply pressure (MPa) Flow rate (l/min (ANR)) 14-8-6 7 Compact Electro-pneumatic Regulator

Basic circuit Cylinder side Cylinder side [Example] 1) [Horizontal] W 3 port normally open SOL.C SOL.B Regulator with relief function SOL.A 3 port normally closed 2) [Vertical] 1) [Horizontal] Load in the direction of rod extension Load in the direction of rod retraction Forward W W Action Forward SOL.A SOL.B SOL.C ON ON OFF Backward Regulator with check valve 0.5 s or more 0 to 0.5 s OFF

CBG1A Air cushion type Locking at both ends 20 25 32 40 CBG1N20-PS-W CBG1N25-PS-W CBG1N32-PS-W CBG1N40-PS-W Above no. @5, @6, @7, @8. And a grease pack. CBG1N Rubber bumper type Locking at both ends 20 25 32 40 CBG1A20-PS-W CBG1A25-PS-W CBG1A32-PS-W CBG1A40-PS-W Above no. @5, @6, @7, @8, $0, $1. And a grease pack.

Nil A B C D q w e q w q w w q e q w The number inside indicates the combination order counted from the inlet side.

Heater assembly quantity 200/40 400/70 400/80 600/130 800/180 1200/300 1600/400 100V H5 120C 800/40 1600/80 1600/80 2400/130 3200/180 4800/300 6400/400 200V The inrush current of the heater flows for several ten seconds when using 100V while it flows for several seconds when using 200V. However, this inrush current decreases momentarily.

175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rod boot Intermediate strokes are available.

7) 0V [1] Power supply input terminals, L1 and L2: Specify power supply to input terminals L1 and L2. [2] Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).

Power consumption reduced 0.45 W 0.35 W CE compliant (Built-in solenoid valve/PB1011A) Check valve is resistant against foreign matter. Flow passage around the check ball is enlarged and improved for better resistance against foreign matter. Longer life [Life is 1.5 times longer than the current product.]

Power consumption reduced 0.45 W 0.35 W CE-compliant (Built-in solenoid valve/PB1011A) Check valve is resistant against foreign matter. Flow passage around the check ball is enlarged and improved for better resistance against foreign matter. Longer life [Life is 1.5 times longer than the current product.]

Standard With power saving circuit 0.4 W 0.1 W 0 W 62 ms 372 Series 10-SYJ3000/5000/7000 Specific Product Precautions 4 Be sure to read this before handling. Refer to page 1382 for Safety Instructions and pages 677 to 683 for 3/4/5 Port Solenoid Valve Precautions.

DC (42 mA), 0.5 W DC (21 mA) 3 position exhaust center 12 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) 2 position double (Metal) (A) 4 (B) 2 (A) 4 (B) 2 100 VAC Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) Power consumption (Current) 110 VAC Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 1 (P) 5 (R1) 3 (R2) 200 VAC Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 1 (P) 5 (R1) 3 (R2) 220 VAC Inrush

Use a regulator or filter regulator with a back flow mechanism when mounting a 3 port valve for residual pressure release on the IN side to ensure the release of the AC25 Rc 3/8 AC55 Rc 1 0 0 200 400 600 800 Flow rate L/min (ANR) 4000 6000 8000 2000 10 0 0 Flow rate L/min (ANR) residual pressure.