SMC Corporation of America
Elite Part Number Search
Search Results "MHQJ2-20C-M9N"

Low temperature operation 1) The valve can be used in an ambient temperature of between 10 to 20C.

Fixed end At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. Max.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).

in the users equipment: 25 kW Power supply: 200 V 60 Hz Circulating fluid flow: 125 L/min@0.5 MPa External piping: Bypass piping + Heat load 21 Conditions 20 19 25 kW load Heat load fluctuation (0 kW 25 kW) 0 kW load 0 10 20 30 40 50 Time [Minute] Applicable to an ambient temperature of 20C.

Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.

(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.

After 15 minutes, cool 32C down to 20C.

of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C.

20C (68F) bend the tubing into a U shape.

Contacts/Bulb gland Pressure Source Nil W Nil B C 1a1b (Standard) 2ab Contact Warning Enclosure Type A 20a (Standard) Type A 20b Type A 20c Bulb gland 1.

factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] V After 15 minutes, cool 32C down to 20C.

O When the ambient temperature is 20C 5C and rated voltage is applied. P Coil change from AC to DC or DC to AC is impossible because the iron core shapes are different.

After 15 minutes, cool 32C down to 20C. HRL200-A Precautions on Cooling Capacity Calculation 1. Heating capacity When the circulating fluid temperature is set above room temperature, it needs to be heated by the thermo-chiller. The heating capacity depends on the circulating fluid temperature.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) For details, please contact SMC.

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

A 10 () (+) White Black Conductor resistance /km, 20C Station 10 65 or less SOL. B 23 () (+) Gray Red 11 () (+) White Red SOL. A Withstand pressure V, 1 minute, AC Station 11 1000 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Insulation resistance M/km, 20C Station 12 5 or less SOL. B 25 () (+) White None Note) The minimum bending radius for D-sub connector cables is 20mm.

Connector structure ZSE/ISE40, 80 Series Available Mounting Options Series IP40 IP65 20 20A 20B(-L) 20C With waterproof cover (20B, 20C) Lead wire Mounting Available Mounting Options Series Bracket A Bracket B Bracket C Panel mount 20 20A 20B(-L) 20C The bracket configuration allows for mounting in four orientations.

capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 8.4 [kW] HED V After 15 minutes, cool 32C down to 20C.