LXPB2SB-B LXPB5SA-B LXPB2BC-B LXPB5BC-B LXPB2BD-B LXPB5BD-B LXPB2SA-B 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 Sanyo Denki Co., Ltd. 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 LXSH5SB LXSH2SB LXSH5SA LXSH2SA LXSH5BC LXSH2BC LXSH5BD LXSH2BD LXSH5SB-B
x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYV15 CYV32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m: Load mass [kg] L: Distance to load center of gravity [mm] A, B: Distance to guide shaft [mm] g: Gravitational acceleration [9.8 m/s2] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Central axis of guide Central
*Refer to the table of Applicable stroke 6mm 6mm 8mm 8mm 10mm 10mm B B Cable type *Applicable stroke Standard produced upon receipt of order Without cable Nil Without cable Nil 100 100 200 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 Robotic type cable R Robotic type cable R 11-LEFS25 11-LEFS25 Standard cable S Standard cable S 11-LEFS32 11-LEFS32 Motor cable
B 23.5 A 7.0 B A 10.5 (13.0) B Bore size 50 63 80 23.5 19.5 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values inside ( ) are for the D-A96/A96V.
N.O. 0.4 0.3 0.2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure (MPa) Flow Characteristics/Weight C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Effective area (mm2) Pilot port size Type of actuation Port size SYJA312-M3 SYJA322-M3 SYJA314-M5 0.41 0.18 0.086 0.35 0.33 0.086 Body ported N.C. N.O. N.C.
0.07 10 0.88 (22.4) 0.00 0 0 100 200 300 400 500 600 700 800 Flow rate (slpm, N2) 2 x 10-32 UNF depth 0.3 (7.6) (Mounting hole) AP1402TA Inlet pressure: 0 psig (0 kPa) 760 0 -8 700 Delivery pressure (mm Hg abs) -21 600 Delivery pressure (kPa) -35 500 Connections A B -48 400 inch (mm) inch (mm) FV4 MV4 TW4 FV6 MV6 TW6 FV8 MV8 TW8 3.70 4.00 3.46 (94.0) (101.6) (87.9) -61 300 2.00 (50.8) -75
Circulating fluid return port When heating the circulating fluid, the high-pressure, high-temperature refrigerant gas is bypassed into the evaporator by expansion valve B to heat the circulating fluid. The combination of the precise control of expansion valve A for cooling and expansion valve B for heating allows for high temperature stability.
F B With pressure at head side With pressure at rod side *Refer to p.5.3-2 for further information on the auto switch.
flats C G E H B NN Effective thread length T (R) NA Q N F NA I F N CC 0.1 + 12-CY3B50, 63 12-CY3B6 to 15 (mm) B 17 25 35 36 46 60 70 86 100 0.007 0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22 29 33 33 I 28 34 40 50 58 72 J 4.5 4.5 6 6 8 8 10 12 12 N 9.5 11 11 18 18.5 20
4-FD Port 32 40 50 63 80 100 up to 700 25 79 32 64 10 3 7 50 C85 up to 800 31 90 36 72 10 3 9 55 up to 1000 38.5 110 45 90 12 2 9 70 Fd FY B CG1 up to 1000 39.5 120 50 100 12 2 9 80 up to 1000 45.5 153 63 126 16 4 12 100 up to 1000 54 178 75 150 16 4 14 120 FX FE FT MB FZ C95 Rear flange(G)/Locking at head end (Hl) Hl/ Rl Wl (mm) CA1 Cushion valve Stroke range Bore size (mm) ZZ ZZ FZ FY FX
A B A B B A B A B A B B A B A B A 10 16 2 2 6 6 2.5 2.5 1.5 1.5 0.5 0.5 4.5 4.5 3 3 3.5 3.5 8.5 8.5 0.5 0.5 2.5 2.5 6.5 6.5 3 3 2 2 1 1 5 5 3.5 3.5 4 4 9 9 1 1 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
D-K39 D-K39C D-A5m D-A6m D-A3m D-A3mC D-A44 D-A44C Auto switch model D-G5m D-K59 D-G5NT D-G5mW D-K59W D-G5BA D-G59F D-F5m D-J59 D-F59F D-F5mW D-J59W D-F5BA D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-B5m D-B64 D-A9m D-A9mV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 9 9 5 5 2.5 2.5 4.5 4.5 2 2 5.5 5.5 3 3 10.5 10.5 0 0 1 1 0 0 50 9.5 8.5 5.5 4.5
Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.
(c) (a) (b) (c) (b) (c) (a) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) (b) (c) (a) (b) (c) Note 1) The above (a), (b), (c) indicate heater mounting positions.
SYJ300/500/700 Preferred Option Summary Option Light and surge voltage suppressor Series Type of actuation Voltages Electrical entry Manual override Manifolds L type plug connector SYJ300 Type 42 N.C. N.O.
2 (A) 4 (B) 2 Note) Not applicable to S kit. 1 A Note) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) Coil voltage B: Locking type (Slotted) N.C N.C 12 VDC 5 6 4 position dual 3 port valve (B) 2 position double (metal) 24 VDC Note) (A) 4 (B) 2 (A) 4 (B) 2 B Note) S kit is only available for 24 VDC.
When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .
Basic style: CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G RE A B REC CX D E CY H1 MQQ M AL B1 K A N F N B C M S + Stroke H RHC ZZ + Stroke MK(2) RS Q G (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92