SMC Corporation of America
Elite Part Number Search
Search Results "PF2M721-C8-L4"

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: NPN; Out 2: NPN, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Panel Mount Adapter, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Panel Mount Adapter, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Panel Mount Adapter, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Metric size Inch size M D1 Model number Piping thread 6 1/4 3/8 1/2 10 12 8 Pilot port (5/16) ASP330F-U01-X352 1/8 Uni-fit G 1/8 L1 T ASP430F-U02-X352 1/4 Uni-fit G 1/4 ASP530F-U03-X352 3/8 Uni-fit G 3/8 D2 ASP630F-U04-X352 1/2 Uni-fit G 1/2 H L2 Note) Additional models are possible (i.e. thread form/tubing size combinations), please contact L4 your SMC representative for availability.