Model: 10S3 (Side Ported), SI Unit Specification: V (CC-Link), Valve Stations: 8 Stations, P, E Port Location: U (U Side), SUP/EXH Block Assembly: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: V (CC-Link), SI Unit Common, End Plate: 5 (Negative Common, 7/8" Connector), I/O Unit Stations: None, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: V (CC-Link), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: 1 Station, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: D (Port Location D Side, Internal Pilot), A, B Port Size: C6 (ø6 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: V (CC-Link), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 6 Stations, P,E Port, SUP/EXH Assembly: U (Port Location U Side, Internal Pilot), A, B Port Size: C6 (ø6 One-touch Fitting)
/Surge Suppressor, Polar Type), Switch: None, Manual Override: Non-locking Push Type, A,B Port Size: C6 (ø6 One-touch Fitting, Straight)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
: C6 (ø6 One-touch Fitting), Mounting Option: Mounting Screw, Round Head Combination Screw, Wiring Specification: WO (w/o M12 Connector Cable), Port Location: V (Top Ported [1 (P), 5 (EA), 3 (EB) Port: Side Ported])
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: V (6VDC), Electrical Entry: MN (M Plug Connector w/o Lead Wire), Lead Wire Length: None, Surge Suppressor: R (Surge Suppressor Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: C6 (Body Ported ø6 One-touch Fitting), Thread
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: V (6VDC), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: C6 (Body Ported ø6 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: V (CC-Link), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 12 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: V (CC-Link), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 10 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: V (CC-Link), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: D (Port Location D Side, Internal Pilot), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: V (CC-Link), SI Unit Common, End Plate: 3 (Positive Common, 7/8" Connector), I/O Unit Stations: None, Valve Stations: 10 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: BA (Direct Mounting,
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: V (CC-Link), SI Unit Common, End Plate: 3 (Positive Common, 7/8" Connector), I/O Unit Stations: 1 Station, Valve Stations: 10 Stations, P,E Port, SUP/EXH Assembly: F (Port Location Both Sides, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: BA (Direct Mounting
SI Unit: V (Mitsubishi CC-LINK System), Stations: 7 Stations, PE Port Location: U (U Side 2~10 Stations), Pilot: S (Internal Pilot, Built-in Silencer), A, B Port: C6 (ø6 One-touch Fitting)
, Manual Override: D (Push-turn Locking Slotted Type), A,B Port Size: C6 (ø6 One-touch Fitting, Straight)
Override: Non-locking Push Type, A,B Port Size: C6 (ø6 One-touch Fitting, Straight)