Stations: 04 (4 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: S (w/Flow Adj.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: F (Integrated Display;
Stations: 04 (4 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: J (Integrated Display; Instantaneous Flow: L/min; Accumulated
.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
.: PNP; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
20 m 50 m 100 m Thickness (mm) 0.5 0.05 1.2 0.12 1.5 0.15 0.8 0.08 0.8 0.08 0.5 0.05 Bundle 16 m (50 ft) 33 m (100 ft) 2 m Straight pipe Color Applicable fluid Applicable fittings Translucent (color of material) Refer to the applicable fluid in page 511.
Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.
Particle diameter (m) Particle diameter (m) Front matter 23 Comparison of Cleanliness Standards ISO 14644-1 ISO Cass 1 to 9 Intermediate classes available U descriptor: Particles smaller than 0.1 m M descriptor: Particles larger than 5.0 m Standard Fed.Std.209E British unit: Class 1 to 100.000 SI unit: Class M1 to M7 U descriptor: Particles diameter smaller than 0.1 m (SI unit) (British
[1 m]/Height 3.3 ft [1 m]) Note 5) dB (A) 70 Waterproof specication IPX4 Electrical system Accessories Alarm code list stickers 2 pcs.
Particle diameter (m) Particle diameter (m) Front matter 23 Comparison of Cleanliness Standards ISO 14644-1 ISO Cass 1 to 9 Intermediate classes available U descriptor: Particles smaller than 0.1 m M descriptor: Particles larger than 5.0 m Standard Fed.Std.209E British unit: Class 1 to 100.000 SI unit: Class M1 to M7 U descriptor: Particles diameter smaller than 0.1 m (SI unit) (British
(mm) 4 4 6 6 8 10 Piston rod thread M4 x 0.7 M4 x 0.7 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.25 Space-saving Port size M 5 x 0.8 M 5 x 0.8 M 5 x 0.8 M 5 x 0.8 G 1/8 G 1/8 Mounting accuracy and rigidity made possible by means of faucet joint and direct mounting.
= 0.7375 ft lb 1 N m = 0.7375 ft lb MXH10 MXH10 0.3 0.3 60 60 50 0.25 0.25 Displacement (mm) Displacement (mm) Displacement (mm) Displacement (mm) 40 50 0.2 0.2 25, 30 40 Stroke Stroke Stroke 15, 20 0.15 0.15 25, 30 5, 10 0.1 0.1 15, 20 5, 10 0.05 0.05 0 0 0 0.17 0.33 0.50 0.67 0.82 0.20 0 0.37 0.57 0.76 0.96 Yaw moment My(Nm) Pitch moment Mp(Nm) 1 N m = 0.7375 ft lb 1 N m = 0.7375
Nil(Example) Y69B 3 m L (Example) Y69BL 5 m Z (Example) Y69BZ Notes) Solid state switches marked are produced upon receipt of order.
Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Applicable load Lead wire length (m) Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 1) Lead wire length symbols: 0.5 mNil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
) / CAN_L Low FG(DRAIN) VDeviceNet T T T 6m T T DataRate 500kbps 100 m 6 m 39 m 250kbps 250 m 78 m 125kbps 500 m 156 m 100 m 121 1%(1/4 W) DeviceNet AWG18 (0.82 mm 2) AWG15 (1.65 mm 2) AWG24 (0.20 mm 2) AWG22 (0.33 mm 2) 120 10%(1 MHz) 120 10%(1 MHz) 1.36 ns/ft(max.) 1.36 ns/ft(max.) 0.13 db/100 ft@125 kHz(max.) 0.25 db/100 ft@500 kHz(max.) 0.36 db/100 ft@1 MHz(max.)