Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS G 1/2 VFS 2-5 (Mounting hole) 3-2.3 (Electrical entry) VS4 VQ7 Light/Surge voltage suppressor (At FZ) EVS VFN 2-Rc 1/8 (EA, EB port) 3-Rc 1/8, 1/4 (P , A, B port) ( ): Rc 1/8 01 02 01 02 01 02 2 position double:
Contents Contents @1 @2 @3 @4 Piston seal MGP12-Z-PS MGP16-Z-PS MGP20-Z-PS MGP25-Z-PS MGP32-Z-PS MGP40-Z-PS MGP50-Z-PS MGP63-Z-PS MGP80-Z-PS MGP100-Z-PS 12 16 20 25 32 40 50 63 80 100 Rod seal Set of left nos. @1, @2, @3, @4 Set of left nos. @1, @2, @3, @4 NBR Gasket A Gasket B Seal kit includes @1 to @4. Order the seal kit, based on each bore size.
of 6P (L, R, Z) is 0.2 to 0.6 MPa (30 to 90 psi). 2 For pipe thread type: NPT only.
VX 2 2 21 01 1 G 1 1 1 G Normally Closed (N.C.)
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.
Solenoid valve (Port size) D, T G, C S S L, Z S L, Z T 1 (2mm) 2 (3mm) 3 (4.5mm) 4 (6mm) 5 (8mm) 6 (10mm) VX21 VX22 VX23 (1) 01( ) 02( ) 02( ) 03( ) 04( ) 02( ) 03( ) 04( ) 1 8 1 4 1 4 1 4 3 8 1 2 AC 3 8 1 2 Ordering Example (Example) Series VX21, Orifice size 2 mm, Rc(PT)1/8, 100V AC Grommet. With surge voltage suppressor.
Base type 01, 01T, 10: 2 to 15 stations 01C, 01F: 2 to 8 stations Blanking plate (Filter, Regulator) Blanking plate (Pressure switch) Stacking type Integrated type Nil 1 Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Symbol Note) Stacking type: Base type 01, 01T Integrated type: Base type 01T, 01C, 01F Passage Porting specifications B, A EA, EB P Thread type
C NC Autodrain D NO Autodrain P O R T S I Z E 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 14 1 1/2 20 2 T H R E A D Rc(PT)* Remove (N) when ordering F G(PF)* Remove (N) when ordering N NPT Courtesy of Steven Engineering, Inc. !
Fig 2-2 Part number of product(2/2) 2.1 Model Number of Product HRR Series 2-2 HRX-OM-X071 Chapter 2 Name and Function of Parts 2.2 Name and Function of Parts 2.2.1 HRR050-A-20/40(Air cooled type) In the case of option Z, without bypass valve Fig 2-3 Names of the parts Table 2-1 Accessory list 2 copies Operation manual (English 1 copy/ Japanese 1 copy) Power supply connector 1 pc.
SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 SY100-82-2-02 SY100-82-2-03 SY100-82-2-04 Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Circuit Diagram with Light AC DC AC circuit DC circuit Connector Assembly with Cover: Dimensions (40) Gray 1 2 1 2 (10) (8) (4.1) (6.9) Red Black R NL NL: Neon light R : Resister R LED (8) LED: Light emitting diode R : Resister
0.005~0.4 MPa / 0.7~60PSI 2 0.005~0.8 MPa / 0.7~120PSI For Series IR3000 0 0.01~0.2 MPa 1 0.01~0.4 MPa 2 0.01~0.8 MPa T H R E A D T Y P E Rc(PT) N NPT F (G)PF S Y M B O L S ACCESSORIES S E R I E S IR1000/2000/3000 Model IR1000 IR1010 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 Bracket P36201023 P36202028 P36203018 Pressure Gauge G33-2-01 G33-4-01 G33-10-01 G43-2-01 G43-4-01
to left V V V V V + r b Unit Nil Unit on product label: MPa V V V V V Z*2 Unit on product label: psi v*3 v*3 v*3 v*3 v*3 *1 The pipe thread type for the EXH port is G. *2 For the pipe thread type: NPT only.
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Setting range: MT.01 to MT.05 (Initial value: MT.01) Contact output signal 2 Select function 17. Press the [] key. Displays screen for setting the function for the Contact output signal 2. Contact output signal 2 function DOUT2 SEL(Alternately displayed) Displays the function for the Contact output signal 2.
300 mm 6 600 mm 10 1000 mm 15 1500 mm 20 2000 mm 25 2500 mm 30 3000 mm 50 5000 mm 51 Series SYJ7000 2 Position Single [ ]: AC G H G H Grommet (G), (H): SYJ7120-01 With bracket: SYJ7120-01-F 44 36 2-4.5 (For mounting) 4 26 34 + G: Approx. 300 H: Approx. 600 (Lead wire length) 82 [84.2] 59.8 24.1 28.3 39.5 [46.5] 13 B A 3 Manual override 2-3.2 (For manifold mounting) 35 17 1/8 (A, B port)
Z1. 2 Excluded for option Z.