LB LC LD LE LF LH LT Model LA MM U FD FT FX FY ZX ZY F H Model M 6 x 1.0 depth 12 200 (233) 224 (257) CRA1L50 CRA1F50 41 62 9 44 4 39 108 4.5 114 9 13 90 50 110 81 M 6 x 1.0 depth 12 235 (273.5) 263 (301.5) CRA1L63 CRA1F63 48 76 11 55 5 45 127 5 136 11.5 15 105 59 130 101 M8 x 1.25 depth 16 274 (318) 316 (360) CRA1L80 CRA1F80 58 92 13 67 5 55 154 6 165 13.5 18 130 76 160 119 M10 x 1.5 depth
5 Pilot valve assembly How to Order Pilot Valve Assembly SCZ2 G 1 1 Rated voltage Series VZ200 1 100 VAC, 50/60 Hz Pilot pressure exhaust Manual override Electrical entry 2 200 VAC, 50/60 Hz 1 Spacer side exhaust (Type 20) 3 110 VAC, 50/60 Hz Nil Push type (Safety style) G H L LN L plug connector With lead wire 600 mm lead wire 300 mm lead wire 4 220 VAC, 50/60 Hz Grommet B Locking type
Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175
V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option) CH1 0.1 15 to 25 HRL Inverter dual type 26 kW Indoor use 19 kW 9 kW CH2 0.5 20 to 40 1.0 kW (Max. 1.5 kW) 322 Circulating Fluid Temperature Controller Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series
The spacing of the side support must be no more than the values shown in the graphs at right. 200 200 190 190 (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) (2400) 130 130 l (1800) (1800) (1800) 120 120 Weight m (kg) Weight m (kg) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) 90 90 (1500) (1500) (1500) MY1CW63 MY1CW63 m 80 80
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
110 110 MXW25 50 100 200 300 500 700 Piston speed (mm/s) Piston speed (mm/s) Graph (3) Graph (2) Static Moment Moment generated by the workpiece weight even when the cylinder is stopped L2 B1 Yaw moment My = W x 9.8 (L2 + B) Roll moment Mr = W x 9.8 (L3 + C) Pitch moment Mp = W x 9.8 (L1 + A1) A1: Moment center position distance compensation amount B1: Moment center position distance
220 77.5 80 50 40 18 9 88 35 9 4.6 74 3 226 187 38 110 235 93 96 70 50 20 11 115 44.5 11 6.4 84 3.3 303 264 43 110 282 98 96 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 279 45 110 292 98 101 70 50 20 11 11 6.4 117.5 84 44.5 3.3 318 280 46 110 297 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
Plug-in, With light/surge voltage suppressor (Only for plug-in manifold) F Coil rated voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other L plug connector, With lead wire With light/surge voltage suppressor L L plug connector, Without connector With light/surge voltage suppressor LO For the special voltages, please consult
74 60 820 263 86 70 0.05 AN300-03 3 8 AN400-04 1 2 0.02 AN500-06 3 4 0.01 AN600-10 1 1 1 0.005 AN700-12 1 4 AN800-14 1 2 AN900-20 0.002 50 200 1000 5000 20 100 500 2000 10 50 10 Construction/Parts/Dimensions Air flow (l/min (ANR)) AN500 to 900 AN200 to 400 Noise Level (Initial conditions) End plate End plate AN200 to 900 Condition: 0.5 MPa at inlet pressure of solenoid valve Measurement
Ball screw 0.03 80 3 100 Slide screw 0.05 200 2 Guide rod type Series LXP 200 3 Slide screw 0.05 100 4 Without motor brake 30 Ball screw 0.03 6 80 Ball bushing guide 100 Slide screw 0.05 Sanyo Denki Co., Ltd. 200 2 200 3 Slide screw 0.05 100 4 With motor brake 30 Ball screw 0.03 5 80 100 Slide screw 0.05 200 3 High rigidity slide table type Series LXS 200 4.5 Slide screw
70 158 124 142 63 M10 x 1.5 9 M10 x 1.5 WA WB Bore size (mm) VB X XA XB XC XL YY YL Z st25 25
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 1000 500 Not available with air cushion. Other strokes available on request.
1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC 3 position double check 3 position exhaust center Inrush 2.6 VA (11.7 mA), Holding 2.6 VA (11.7 mA) 220 VAC (A) 4 (B) 2 (A) 4 (B) 2 Note 1) Use dry air to prevent condensation when operating at low temperatures.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Type Nozzle model Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 KNL3-06-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 Nozzle size Standard type Nil 01 02
Nonstandard Compatible Motors: Motor model Corresponding driver model Power supply voltage (AC) Motor output (W) MSM011P1A Matsushita Electric Industrial Co., LTD 100/115 MSD011P1E MSM012P1A 100 200/230 MSD013P1E 100/115 MR-C10A1 Mitsubishi Electric Corporation HC-PQ13 100 200/230 MR-C10A Yaskawa Electric Corporation 100/115 SGDE-01BP 100 SGME-01BF12 200/230 SGDE-01AP SGME-01AF12 Refer to
to 700 20 31 8 6 48 49.5 56.5 16 18 12 22 45.5 36 19.5 200 to 700 25 38 9 6 51 51.5 55 19 18 12 22 51.5 44 19.5 200 to 1000 32 47 11 8 54.5 51.5 56 21 20.5 16 24 61.5 53 21 200 to 1000 40 N NE NA NB NF ND NN P S WH ZZ MM K JD JC Bore size (mm) 252 1/4 192 15.0 13 M22 x 1.5 30 26 M8 x 1.25 33.5 22 5 30.5 43 20 5.8 to 8.8 257 1/4 193 19.6 17 M24 x 1.5 36.9 32 M10 x 1.25 37 27 5.5 25.5 39 25
. * There is no S option for AC voltage valves because the generation of surge voltage is prevented by a rectifier. u Manual override H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector Nil Non-locking push type D Push-turn locking slotted type AC (50/60 Hz) CE-compliant 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] * LN and
170 200 50 152 MHL2-16D2Z 90 95 110 78 130 210 240 70 192 J dimension is at fully closed.
200 300 300 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 150 150 0.3 MPa 0.3 MP 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 200 200 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 100 100 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80