SMC Corporation of America
Elite Part Number Search
Search Results "SGC221A-1010Y-5DZ-B1"

This is a legacy product, and replaced byVK334-5DZ-01-Q VK300 SOL VALVE 3-PORT. VALVE, SGL SOL, BASE MT. VALVE. VK300 BASE MT 1/8. .64059 lb. NA.

This is a legacy product, and replaced byVNC314A-20A-5DZ VNA/B/C/D 2-WAY MEDIA VALVE. COOLANT VALVE. VALVE. VNA/B/C/D BODY PT >3/4. 2.42230 lb. LA.

This is a legacy product, and replaced byVFS6110-5DZ-Q VFS6000 SOL VALVE 4/5 PORT. VALVE, SOL. VALVE. VFS6000. 7.75336 lb. 2D.

This is a legacy product, and replaced byVNC211A-10A-5DZ-B VNA/B/C/D 2-WAY MEDIA VALVE. VALVE, COOLANT. VALVE. VNA/B/C/D. 1.69570 lb. 1A.

This is a legacy product, and replaced byVFS4310-5DZ-04T

This is a legacy product, and replaced byVK334Y-5DZ VK300 SOL VALVE 3-PORT. VALVE, SOL, BASE MOUNTED. VALVE. VK300 NO SIZE RATING. .24526 lb. 2A.

H1 2-IA D MM Effective thread 3 A F NB NC K H S + Stroke ZZ + Stroke NA I 3 (mm) Effective thread length (mm) IA (tolerance) Bore size (mm) Stroke range (mm) A B1 B2 D F GA GB H H1 H2 I K MM P S NN N NA NB NC ZZ -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 18 13 26 10 16 12 8 41 5 8 30 5 M8 x 1.25 1/8 81 M22 x 1.5 13 26 19 15 138 23 f8 15.5 to 800 25 22 17 32 12 16 12 8 46

H1 2-IA D MM Effective thread 3 A F NB NC K H S + Stroke ZZ + Stroke NA I 3 (mm) Effective thread length (mm) IA (tolerance) Bore size (mm) Stroke range (mm) A B1 B2 D F GA GB H H1 H2 I K MM P S NN N NA NB NC ZZ -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 18 13 26 10 16 12 8 41 5 8 30 5 M8 x 1.25 1/8 81 M22 x 1.5 13 26 19 15 138 23 f8 15.5 to 800 25 22 17 32 12 16 12 8 46

T V D IA H1 H2 GA1 GB1 2-Rc P Effective thread GA3 3 GB3 A K F NA H NB Air release Air release Air release S + Stroke ZZ + Stroke W I (mm) Effective thread length (mm) Bore size (mm) Stroke range (mm) A B1 B2 D E F GA1 GA2 GA3 GB1 GB2 GB3 H H1 H2 I 20 18 13 26 10 8 16 10 12 12 8 10 10 41 5 8 31 25 to 300 15.5 25 22 17 32 12 10 16 10 12 12 8 10 10 46 6 8 34 25 to 400 19.5 32 24 22 38 16 14

( ) (1) (B1B2) B1 B1 DC24V DC24V U B DC24V U B DC24V VAR VAR B2 B2 B1B2 (2) (3) (a) R[]:() L[H]:() Vb[V]: U DC24V Vs[V] N () 13.1.2 13 2 13.

C R E (AC type) [mm] Model Port size P B B1 C D E F B B1 2 x P Port size VDW1 M5(M6) 20 10 46.1 15 9.5 11 VDW2 M5(M6) 22 11 50.9 20 9.5 13.5 Mounting bracket dimensions Electrical entry Model Port size P U W X Y Grommet Q R VDW1 M5(M6) 28 11 34 17 15.5 30.35 VDW2 M5(M6) 33 14 39 20 17 33.9 464 A Compact Direct Operated 2 Port Solenoid Valve VDW Series Air Medium vacuum Water Dimensions

H1 2 x IA D MM Effective thread 3 A F NB NC K H S + Stroke ZZ + Stroke NA I 3 (mm) Effective thread length (mm) IA (tolerance) Bore size (mm) Stroke range (mm) A B1 B2 D F GA GB H H1 H2 I K MM P S NN N NA NB NC ZZ 0.020 0.053 0.020 0.053 0.025 0.064 0.025 0.064 20 Up to 800 15.5 18 13 26 10 16 12 8 41 5 8 30 23 f8 5 M8 x 1.25 1/8 81 M22 x 1.5 13 26 19 15 138 25 Up to 800 19.5 M10 x 1.25

Applicable bore (mm) d H1 B1 C1 4T counterbore A' 6 10 16 20 25 32 NTP-006 NTP-010 NTJ-015A NT-015A NT-02 NT-03 M3 x 0.5 1.8 2.4 4 5 5 6 5.5 7 8 10 13 17 6.4 8.1 9.2 11.5 15.0 19.6 S + Stroke Auto switch M4 x 0.7 Z + Stroke M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 Bore size (mm) A A' B C D E GA GB H J K L MM NN P Q QA 6 10 16 20 25 32 7 10 11 12 15.5 19.5 10 10 11.5 12.5 13 12.5 12.5 14 18

B B1 B 2 x Port size 1(IN), 2(OUT) port A G G 2 x M thread depth N 2 x M thread depth N CS: Conduit D F K 500 NPT1/2 C J IN E B1 B A 2 x Port size 1(IN), 2(OUT) port G 2 x M thread depth N [mm] Size Port size A B B1 C D E F G M N 20 1/8, 1/4 19 43 21 64.3 36 9.5 18 12.8 M4 6 30 1/4, 3/8 24 45 22.5 80.7 42 12 21 19 M5 8 Size Port size Grommet Grommet with PCB Conduit J K J K J K 20 1/8,

A 20 HRS Options Cooling capacity None Nill 100 10kW Castersadjuster foots A 150 15kW Earth leakage breaker B Earth leakage breaker B1 with a handle B1 Cooling method Fluid fill port K A Air-cooled refrigeration W Water-cooled Fixed SI unit W refrigeration *1 : In case of power supply '40/46', this is standard.

AED ( () 150 1. 2. ) 15.12.5 (A37)(A37) 1 Spd Acc Dec 15 112 16. 16 .2 16.1 .2 16.1.1 .2 16.1.2 .4 16.2 .5 16.3 .5 16.4 .5 16.5 .6 16 1 16. 16 16.1 16.1.1 ( ) (1) (B1B2) B1 B1 DC24V DC24V VAR U B V VAR U B DC24 V DC2 4 B2 B2 B1B2 (2) (3) (a) R[]:() L[H]:() Vb[V]: U DC24V Vs[V] N () 16.1.2 16 2 16.

34.5 PAX PB 25 C E C M G 1/2 K G 1/2 B1 3-Rc P E Bracket A 10.5 K B1 B2 Hexagon width across flats 22 A B1 N B2 3-Rc P B1 Bracket H J K L M L M L M L M N N Grommet Conduit DIN terminal Conduit terminal Electrical entry Port size P Rc , , , B Mounting A C D E F Model 22.5 B1 B2 38.5 47 54 47 48 50 92 95 97 38.5 47 55 59 62 64 14.5 17 17 6 7.5 7.5 23 25.5 28 46.5 55 62 39 41.5 44.2 38.5 47

HED * Cannot be selected together with option B1. HEA IDH Option symbol B1 With Earth Leakage Breaker with Handle HRS 20 B1 With earth leakage breaker with handle A breaker operation handle that can be operated without removing the front panel for the electrical unit is mounted.

Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150

B1 Supply valve (N.O.), Release valve (N.C.)