AXT661-12AL AXT661-12AL AXT661-14AL AXT661-14ANL AXT661-13ANL AXT661-13AL 300mm 300mm AXT661-14AL-6 AXT661-14ANL-6 AXT661-13ANL-6 AXT661-13AL-6 600mm 600mm AXT661-14AL-10 AXT661-14ANL-10 AXT661-13ANL-10 AXT661-13AL-10 1000mm 1000mm AXT661-14AL-20 AXT661-14ANL-20 AXT661-13ANL-20 AXT661-13AL-20 2000mm 2000mm AXT661-14AL-30 AXT661-14ANL-30 AXT661-13ANL-30 AXT661-13AL-30 3000mm 3000mm Note) When
(Blanking plate assembly) DXT192-52-1-4A 3 pcs. (Connector assembly) DXT192-52-2-4A 3 pcs. (Connector assembly) The asterisk denotes the symbol for assembly.
9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring will be double wiring (connected to SOL. a and SOL. b) regardless
However, the maximum number of stations is 16. 1B 2A 2B 3A 3B 4A VFR 4B 5A 5B 6A 6B 7A 7B VQ7 1.
(Manifold specifications sheets are on pages 30.)
VQZ 2B SOL.A 3A () (+) SOL.A 3A SOL.B 3B () (+) 3 stations SOL.B 3B VQD SOL.A 4A () (+) SOL.A 4A SOL.B 4B () (+) 4 stations SOL.B 4B 2. Wiring specifications Connections begin with the A side solenoid of the first station being connected to terminal no. 1, and continue in the order indicated by the arrowsin the drawing without skipping any terminals.
Note) Apparent power (VA) [Current mA] AC Holding 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Option Part no.
SOL.A 3A SOL.B 3B Station 3 SOL.A 4A SOL.B 4B Station 4 SOL.A 5A 10A COM 10B SOL.B 5B Station 5 SOL.A 6A SOL.B 6B Station 6 SOL.A 7A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 7B Station 7 Double wiring (connected to SOL. A and SOL.
VJ10-20-4A-6 2 pcs. 5A 10 ZS ZP (For DC) 4A 20 VJ10 6 Lead wire length ZCU Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 AMJ (For 110 VAC) Note) If ordering switch with 5 m lead wire, specify both switch and lead wire with connector part numbers. Ordering example) ZX100-K150Z-ECN1 pc. VJ10-20-4A-6 2 pcs. ZS-10-5A-50 1 pc. 3A 36 VJ10 6 Misc.
SOL.A 3A () (+) Station 3 SOL.B 3B () (+) SOL.A 4A () (+) Station 4 SOL.B 4B () (+) SOL.A 5A () (+) 2.
0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (mm) Size: 80 Size: 100 30 50 0.4 (MPa) 0.4 (MPa) 25 40 0.3 (MPa) 0.3 (MPa) Lifting force (N) Lifting force (N) 20 30 0.2 (MPa) 15 0.2 (MPa) 20 10 0.1 (MPa) 0.1 (MPa) 10 5 0 0 0 1 2 3 4 5 6 7 8 9 10 Distance from the workpiece (
LEC-CSS-L 11.2 11.2.1 [W] LECLECMR-RB-032 MR-RB-12 [40] [40] LECSS2-T5 30 LECSS2-T7 10 30 100 LECSS2-T8 10 30 100 LECSS2-T9 20 30 100 11 8 11. 11.2.2 [Pr. PA02] [Pr. PA02] 0 0 00: 100W 200W, 400W, 750W 02:LEC-MR-RB-032 03:LEC-MR-RB-12 11.2.3 11.5 100 5m 11 9 11. (1) LECSS2-T P+DP+CG3G4 G3G4 P+D P+D P P+ C C G3 D (3) (1) G4 5m 5 m (12) 1.
Proper tightening torque (Nm) Tightening torques for piping Connection thread Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 5.
AXT632-69-1 AXT632-69-2 VVCA30-3A-04-2 VVCA30-3A-04-1 OR-2200-200-H VCA35--VVCA30-6-n VVCA30-4A-04-2 VVCA30-4A-04-1 No. Part no.
Applicable fitting size Noise reduction (dB) Effective area (mm2) (Cv factor) Series Model A L D d D VQ2000 10 AN20-C10 36.5 57.5 30 16.5 30 Elbow fitting assembly VVQ2000-F-L(C4/C6/C8/N3/N7/N9) It is used for piping that extends upward or downward from the manifold.
Output Specifications 25 (L) 1 output NPN open collector 30 V, 80 mA or less Analog output (1 to 5 V) ZSE4 ZSE4B 26 (L) 67 (L) 1 output PNP open collector 80 mA or less 26 (L) Analog output (1 to 5 V) ZSE4E 27 (L) 2 outputs NPN open collector 30 V, 80 mA or less 67 (L) 2 outputs PNP open collector 80 mA or less 13-3-16 16 Series ZR Large Size Vacuum Module: Ejector System ZX ZR ZM ZH ZU Courtesy
FMW-4200-X4W .5" WC 4" WC 10 0.5" WC 1.2" WC 4A FMW-4200-X5 .2 5 30 .5 .8 4A FMW-4200-X10 .5 5 30 1.0 1.5 4A FMW-4200-X30 1.5 30 30 2.0 3.0 4A 1 Wetted materials. 2 For special deadband or current requirements, contact factory.
FMW-4200-X4W .5" WC 4" WC 10 0.5" WC 1.2" WC 4A FMW-4200-X5 .2 5 30 .5 .8 4A FMW-4200-X10 .5 5 30 1.0 1.5 4A FMW-4200-X30 1.5 30 30 2.0 3.0 4A 1 Wetted materials. 2 For special deadband or current requirements, contact factory.
FMW-4200-X4W .5" WC 4" WC 10 0.5" WC 1.2" WC 4A FMW-4200-X5 .2 5 30 .5 .8 4A FMW-4200-X10 .5 5 30 1.0 1.5 4A FMW-4200-X30 1.5 30 30 2.0 3.0 4A 1 Wetted materials. 2 For special deadband or current requirements, contact factory.