Series: VP700, Pressure Specification: Standard (0.7 MPa), Voltage: 100 VAC, Electrical Entry: DIN Terminal w/Connector, Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Bracket: -, Flow Direction: -
Series: VP700, Pressure Specification: Standard (0.7 MPa), Voltage: 24 VDC, Electrical Entry: DIN Terminal w/Connector, Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Manual, Bracket: -, Flow Direction: -
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal w/o Connector), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Type, Manual)
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum
Series: 7 (VP700), Pressure Specification: Standard (0.7 MPa), Voltage: 5 (24 VDC), Electrical Entry: Y [DIN Terminal (EN175301-803C) w/Connector], Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Type
<br><br>・While it is possible to mount a G36-10-01 or G46-10-01 pressure gauge on a VEX113□/123□ series regulator, it will be larger than the width of the product body.<br>・It is also possible to mount a G46-10-01 pressure gauge on a VEX133 □ series regulator so long as it does not interfere with the piping.
<br>Note) The all side piping option was only added to the VH200 series (as described in ②) in 2016. The VH series catalog can be found here<br><br>
<br><br>For plug lead type manifolds:<br>The max. number of stations that can be increased depends on the wiring kit.
<br>“VVFS2000-22A-1” is the plug-in type perfect spacer part number for the VFS2600.<br>And “VVFS2000-22A-2” is the non plug-in type perfect spacer part number for the VFS2610.<br>The “□” in the VVFS□000-22A-1 and VVFS□000-22A-2 part numbers is to indicate the series (VFS2000/3000/4000/5000 series).<br><br>
<br>Note) A cylinder with a lock may be required depending on the operating conditions.
<br><br>Non plug-in type:<br>Electrical connection is made on the solenoid valve side. Electrical connection is required when replacing the solenoid valve.
<br>Reference) The manifold specification (a VOA301 valve and a VVTA300 base) of the air operated VTA301 series valve can also be changed to from N.C to N.O. by turning over the switching plate in the same way.<br><br>
<br>VS4120, VS4130, and VS3135 series valves with a grommet have 2 lead wires.<br>Connections: For 100 VAC, there are 2 blue wires. For 200 VAC, there are 2 red wires. And for 24 VDC, there is 1 white wire and 1 pink wire.<br>VS4140 and VS3145 series valves have 3 lead wires for AC voltage types and 2 lead wires for DC voltage types.
<br><br>The VSA4□20, VSA4□30, and VSA4□40 series catalogs can be found here.
<br>(They are matched to the individual component dimensions.)<br>Coils of VT317 (VO317) series valves, however, can be ordered, excluding CE-compliant products with the part number suffix “-Q.” Refer to the catalog for the coil assembly part numbers.<br>Do not use coils for DC in valves whose rated voltage is AC, and vice versa.
<br><br>
<br><br>For further details, refer to the catalog of each series.
<br>1) When the product is operated with air supplied to only one side, such as during a test operation<br>2) When the air in the cylinder is exhausted and back pressure cannot be secured during operation<br>3) When a meter-in speed controller is installed and the rise of the supply-side pressure during operation is suppressed<br>4) When the load factor exceeds 50% for vertical downward operation