to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).
n e l D i s p l a y a n d SigmaWin+TM 2.
) With fiflter (80 mesh) 1/8,1/4 (P, A, B port) 3 position closed center/exhaust center/pressure center SYJA7 20-01 3 position closed center/exhaust center/pressure center SYJA7 403 4 5 2-4.3 (For mounting) 3 4 5 01 02 2-3.2 35 34 8.5 (For manifold mounting) 2-M5 x 0.8 (Pilot port) 17 B A 1 34 27 13 1 B A A B 3 1 1 R1 P R2 32.5 45.5 2-M5 x 0.8 31.5 38 (Pilot port) 64 2-3.2 Manual override
For positive pressure 80 ISE 02 N M For vacuum/ compound pressure 80 ZSE 02 N M Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English
32 25 Mounting position A 131.5 180 216 B 88.5 100 124 Operating range l Note) 6 9 10 B A MY1HT (High rigidity/High precision guide type) (mm) 63 50 Mounting position A 290.5 335.5 B 123.5 138.5 Operating range l Note) 5 5 A B 8-11-105 101 Series MY1 Proper Auto Switch Mounting Position (Detection at stroke end) D-Y7W, D-Y7WV Note) The operating range is a guide including hysteresis, but
Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines. Thus, in case of an error, each valve can be turned OFF to minimize the influences on other pads.
a guide, use a solenoid valve with a large effective area for the unlocking solenoid.
Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines.
Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?
MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).
1 Free Mount Cylinder for Vacuum Series ZCUK A free mount cylinder with a vacuum passage in the rod to meet the requirements for Air cylinder + Vacuum pad .
a guide, use a solenoid valve with a large effective area for the unlocking solenoid.
No. 3 4 5 6 7 8 9 Note) When ordering a manifold ZZK2---A on page 3, q to e are delivered as a set.
) ZK2-RL1-A (18) Lock nut(10 pcs. per set) ZK2-LN1-A -36No.
Lead wire with connector for pressure switch for vacuum ZS 39 5G Lead wire with connector for pressure switch with energy saving function ZK2 LW A 20 A Output specifications A NPN open collector B PNP open collector (15) Pressure sensor assembly ZK2 PS 1 A A Rated pressure range and specifications Mounting Note) Nil Mounted to the single unit 1 0 to -101 kPa, Output: 1 to 5 V, Accuracy: 2%
stop (e.g. a large load is mounted on a carrier). 7 11 7.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Mineral oil A A A C A A 18 Sodium hypochlorite (2%, Room temperature) A C D A D B 19 Sodium chloride A A A A B 20 Carbon dioxide A A A A A A 21 Natural gas A A A A A A 22 Boric acid A B D A A B 23 Unless noted otherwise, the solution concentration is in a saturated state.