Data Maximum Settable Temperature Graph 1: IDH4 Graph 2: IDH6 F 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) Air flow capacity scfm (L/min [ANR]) 17.6 (500) 28.3 (800) Air flow capacity scfm (L/min [ANR]) 15.9 (450) Selection example 24.7 (700) 14.1 (400) 21.2 (600) 12.4 (350) Selection example Selection example 10.6

HRZ Series 8.1 Specification 8-3 HRX-OM-I051 Chapter 8 Appendix Specification for ethylene glycol solution (low temperature) Table 8-4 Specification for Ethylene Glycol Aqueous Solution (Low Temperature) Model HRZ001-L1 HRZ002-L1 HRZ004-L1 HRZ008-L1 Cooling method Water cooled refrigerant Cooling capacity*1 (50Hz/60Hz) kW 1.0 (At -10C) 2.0 (At -10C) 4.0 (At -10C) 8.0 (At -10C) Operating

) Circulating fluid system Cooling water system Electrical system 2.0 (at 10C) 1.0 (at 20C) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note

to 70C, With auto switch: 10C to 60C (No freezing) Mounting Bracket Part No.

to 70C Ambient and fluid temperature With auto switch: 10C to 60C (No freezing) Auto switch specifications and the proper mounting positions for stroke end detection are the same as those for double acting, single rod type.

MHZ2-25C/MHZL2-25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa 8 120 0.6 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa F 0.6 MPa 80 0.4 MPa 0.5 MPa 4 60 0.3 MPa 40 0.4 MPa 2 0.25 MPa 20 0.3 MPa F 0 10 20 30 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) Internal Grip MHZ2-10C/MHZL2-10C MHZ2-32C MHZA2, MHZ2, MHZL2 250 Pressure 0.7 MPa Pressure 0.7 MPa

Trace the arrow mark , starting with the point A at the pressure dew point 10C to find the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark , starting with the point B to find the intersection C at the atmospheric pressure dew point. 3.

L SPECIFICATIONS Fluid Air S T D S T R O K E/H U N D R E D T H S O F A N I N C H Proof Pressure 1MPa / 145 PSI 6 (1/4) 050, 100, 150, 200 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 MaxImum Operating Pressure 0.7MPa / 100 PSI 6 0.1MPa / 17 PSI Minimum Operating Pressure 10, 16 0.05MPa / 8.5 PSI Ambient and Fluid Temperature -10C

to 70C With auto switch: 10C to 60C (With no condensation) Proof pressure Max. operating pressure Min. operating pressure Mounting Bracket / Part No.

Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item Bore size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 20 25 32 40 50 63 80 100 10 20 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Stroke

At the same ozone concentration of 1.1ppm, approximately 25% of the ozone still remains in the circuit as measured at point downstream of the mist separator (AM) at an atmospheric dew point of 10C. When the atmospheric dew point is 17C, approximately 45% of the ozone still remains.

Under conditions of inlet air pressure: 0.7MPa, inlet air temperature: 35C, ambient temperature: 32C, outlet air pressure dew point:10C. Note2)

For Use in North, Central and South America Refrigerated Air Dryer (UL, CSA Standards) Applicable for the high-temperature environments Ambient temperature : Max. 113F (45C) Inlet air temperature : Max. 149F (65C) Air flow capacity * IDFB90-23, Dew point of 50F (10C) 459 SCFM (780 m3/h) (13% increase compared to the current model) Power supply voltage Single-phase 230 VAC (60 Hz) Single-phase