PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.
G46-00-00-2 Clear cover Brass Internal parts Mark Weight 80 g Models Specific Product Precautions Pressure range Indicator units Model MPa G46-2-02-SRA Be sure to read this before handling the products.
3 AQ ASV Accessory Body size 1 8 Nil None With bracket 1 3 5 6 AK 8 3 B 3 4 1 Port size ASS Applicable series Port size 01 02 03 04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Rc NPT G Nil N F Meter-in
A White Normally Open B Red Normally Closed Mounting & Wiring ZSE ISE IFW50--01 to 04/11 to 14/21 to 24 Caution PSE 1. Mount a switch, so that the liquid flow is in the same direction as that of the arrow on the body. 2. The flow switch can be installed either horizontally or vertically. 3.
The figure a seal vent $MC PneumatICS' unique figure 8 seal incorporales vents that allow pressufized air to flow into an Integrated cavity forcing the seal firmly against the opposite side 01 the piston seal groove creating a much tighter, more positive barrier against leakage.
VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.
Single Stage Regulator for General Applications Low to intermediate flow Series AK1000 High inlet pressure type: Max. 3500 psig (24.1 MPa) Flow capacity Standard: to 30 slpm HF (option): to 120 slpm Body material: Stainless steel and Brass available Hastelloy internals available for corrosion resistance How to Order Port Number q w e r t AK10 01 4PL 4 4 S 0 0 Delivery pressure Code Connections
ZS-32-A ZS-32-D Refer to Best Pneumatics No. 8 for Pressure Switch Precautions, and the Operation Manual on SMC's website for Specific Product Precautions. 734 Compact Manifold Regulator ARM11A/B Series Common Supply Block ARM11A 1 S 01 3 Z A q w e r t y ARJ AR425 to 935 1. IN Piping Position 2.
1% F.S.30 msAir/Inert gas0 to 50C (With no condensation)0.88 MPa0.05 MPa to supply pressureSet pressure to 0.88 MPa (VY1 01)1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC12 VDC ? 10%, 24 VDC ? 10%, 1.8 W or lessDIN terminalCable O.D. ?
A maximum effective area of 670mm (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 X 30 X 39) and a 3 port, high-capacity exhaust main regulator (VEX1*00 series).
1 3 Port Air Operated Valve Series VPA300/500/700 How to Order SA A 01 2 4 3 VPA VA Option VP Air operated valve None With bracket (Only VPA342, VPA542 and VPA742) Nil F SA Body size VPA542 Passage 3 5 7 1/4 standard 3/8 standard 1/2 standard VA Normally closed Normally open A B Thread type VM NC/NO common 4 Actuation Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,
The calculalion of standard piston speed for kinetic energy at load is ihe average speed x1.2. 225 0 14.s (01) 29 (0.2) 43.5 (0.3) 58 (0.4) e The relation between speed and load is as illustrated below. The range of kinetic energy is under the lineO Al locking. lock-up unit absorbs not only kinetic energy. but also thrust of cvlinder itself.
M typo plug connctor/t{VZ512O.OMOO.01T lngttr 0.13(3.2) DL6 : _ .l : With indicator lisht and su.ge voltage suppressor @ NVZ5000 BodU Portpd lUpe / 2 Position Sitryle Solenoid inch(mm) G.ommet/lnfi Z522GOGOO-01 T t{rzs22GOHOO.{tlT Dlll cornec{o. (D)/ itv:zszar-oDoG01T o.r3(32) Dia 2Mounting hol3 5 .g g I I lc32Nom.
-14No.EX-OMP0004CN-I D 3 -15No.EX-OMP0004CN-I LED LED LED L ERR L RUN PWR ON OFF PWR(V) ON OFF -16No.EX-OMP0004CN-I DIP (0.2 Nm) -17No.EX-OMP0004CN-I 5 L ERRLED 00 65 L ERRLED HOLD/CLEAR HOLD/CLEAR No.1 HOLD ON CLEAR OFF No.2 ON 110 OFF -18No.EX-OMP0004CN-I EX260-SMJI/O (1 32 /32 ) SI [01] QJ61BT11N EX260-SMJ1/2 I/O (1 ) (RY) (RX) (RX) (RY) E0H RX0FRX00
M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: DIN Rail Mouting, Cable Length: 1 m, Inlet Port Silencer: ANB1-01, 55 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: V124-5LU-M5
Controller Mounting: Screw Mounting, Cable Length: 1 m, Inlet Port Silencer: AN10-01, 62 dB, Digital Pressure Switch: ISE20A-Y-01-J-X603, Exhaust Check Valve: AKH06-00, for 6mm tubing, Exhaust Solenoid Valve: -
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)