Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: G

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: M

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF (NW), Valve Direction: w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry:

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 50, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: w/o Auto Switch w/Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 12 VDC, Electrical Entry: M Type Plug Connector, Surge Suppressor:

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: w/o Auto Switch w/Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor:

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: w/o Auto Switch w/Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor:

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 25, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 5m, Number: 2pcs, Valve Open/Closed, Voltage: 110 VAC, 50/60 Hz, Electrical Entry: L Type Plug Connector, Surge Suppressor

Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 63, Flange Type: D [K (DN)], Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: w/o Auto Switch w/Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor

Type: Electromagnetic valve used under high vacuum, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Solenoid Type: Single, Switching Type: 2-Position Normally Closed, Electromagnetic Valve Drive Type: Directly Operated, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 50, Voltage: 12 VDC, Seal Type: Bellows Seal, Sonic Conductance

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: Air cushion on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF(NW), Port Direction: K (w/o Indicator, Left Flange Surface; Std. Indicator, Left Flange Surface), Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 50, Seal Type: Bellows Seal, Sonic Conductance: 80L/S, Valve Type: In-line type, Pilot Port Direction: Flange surface, left, Temperature Range(°C): 5 to 60, Switch

Magnet: Built-in, Mounting: Rear Flange, Bore Size: Ø40, Port Thread: Rc, Stroke: 50mm, Rod Boot and Cushion: Heat Resistant Tarpaulin, Auto Switch: Y59B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -