cleaner for Rc 1: U side exhaust 1 Plug-in unit Exhaust cleaner for Rc 1 1/2: U side exhaust Special wiring specifications (Except double wiring) Stations Direct exhaust with silencer box: For mounting on both D and U sides Connector entry direction 02 2 stations Direct exhaust with silencer box: D side exhaust Cylinder port Direct exhaust with silencer box: U side exhaust ... ... 03 04
LVQ Model VXA212 VXA213 VXA21 VXA22 VX070-020 LQ 1 8 1 4 1 4 3 8 1 2 01 ( / ) 02 ( / ) 02 ( / ) 03 ( / ) 04 ( / ) VXA223 VXA224 VXA225 VXA226 VX070-022 LVN VX070-029 TI/ TIL PA Ordering example (Example) Series VXA21, Orifice size 4.5 mm, Normally closed, Rc 1/4 (Part no.) VXA2130-02 PAX PB 17-3-95 4 The VX series will be revised shortly.
Rc1/4 52 52 21 57 XTO-2571-03 Rc3/8 XTO-1239-02 Rc1/4 84 80 37 79 XTO-1239-03 Rc3/8 Rc1/4 XTO-1239-04 Rc1/2 XTO-1719-06 Rc3/4 98 98 40 90 XTO-1719-10 Rc1 !
VHS400-02 VHS401-02 VHS400-03 VHS401-03 VHS400-04 VHS401-04 VHS500-06 VHS501-06 Pipipng direction Port size 3 4 1 2 3 8 1 4 1(P) 2(A) 21 105 76 54 35 35 57 93 Effective area (mm2) Mass (kg) 2(A) 3(R) 0.25 0.34 The front face of the handle is the reference position. Easy to Operate The direction of air flow can be verified at a glance by the orientation of the handle.
: I-03 32: I-04 40: IHN-04 L tap 4-J counter bore 4-K Material: Rolled steel plate Material: Rolled steel plate RR1 NDH10 A B E F MM RR1 45 MM NDH10 D +0.2 +0.1 M C E1 E1 R UH8 U1 U1 A1 NX A1 L1 L1 NX H I G Applicable bore size (mm) I-02 I-03 I-04 IHN-04 Part no.
-01 KDM20S-03 KDM20S-07 KDM20P-01 20 KDM20P-03 KDM20P-07 KDM20S-09 KDM20P-09 Clamp bolt Panel mounting Loosen (4) screws for bracket on the socket side using a Phillips screwdriver (JIS nominal No. 2) until the bracket touches the stop ring.
AS231F-02 R 1/4 Application to inch size tubing Metric size (Release bushing: White color) 3.2, 4, 6, 8, 10, 12 Inch size (Release bushing: Orange color) 1/8", 5/32", 3/16", 1/4", 5/16", 3/8", 1/2" 40, 50, 63 AS321F-02 AS331F-02 R 1/4 40, 50, 63 AS321F-03 AS331F-03 R 3/8 63, 80, 100 AS421F-04 AS431F-04 R 1/2 Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually
Free flow Controlled flow Weight (g) Sonic conductance dm3/(sbar) Sonic conductance dm3/(sbar) Critical pressure ratio Critical pressure ratio Model Port size Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS1000-M3 AS1000-M5 AS2000-01 AS2000-02 AS3000-02 AS3000-03 AS4000-02 AS4000-03 AS4000-04 AS5000-02 AS5000-03 AS5000-04 0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7
32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for
characteristics Set pressure range (MPa) Without sub-plate Without sub-plate 1 2 3 Nil 02 03 13 9 5 Symbol 2 1/4 Nil 02 03 0.05 to 0.65MPa 1 3/8 2 1/4 2 0.1 to 0.9MPa 2 02 03 04 03 04 06 1/4 3/8 1/2 3/8 1/2 3/4 1 2 3 4 3/8 03 04 06 3 1 30 3/8 0.005 to 0.15MPa 1 4 1/2 4 45 1 3/4 12 8 4.5 2.5 Without sub-plate Nil 02 03 1(P) Symbol Flow type (VEF2) Flow type (VEF3) Pressure type (VEP3) 2 2
Symbol Body size Symbol Standard characteristics Symbol Port size Without sub-plate Rc 1/4 Rc 3/8 1 2 3 Nil 02 03 Symbol Set pressure range (MPa) 2 Without sub-plate Rc 1/4 Rc 3/8 Nil 02 03 03 04 06 0.05 to 0.65 MPa 1 2 2 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 3/4 0.1 to 0.9 MPa 2 02 03 04 03 04 06 1 3 30 Rc 3/8 Rc 1/2 Rc 3/4 4 0.005 to 0.15 MPa 1 1 4 45 1 2 3 4 12 8 4.5 2.5 Without sub-plate
TI/ TIL Table (2) Rated Voltage-Electrical Entry-Electrical Option Table (1) Connection Size and Applicable Model PA Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G Connection Applicable model VXD2130-02 VXD2130-03, VXD2140-03 VXD2130-04, VXD2140-04 VXD2150-06 VXD2260-10 VXD2270-32 VXD2380-40
Table(2) Rated Voltage-Electrical Entry-Electrical Option PAX Table(1) Connection Size and Applicable Model Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G C D, T G, C T PB S L, Z S L, Z S Note ) Connection Applicable model VXP2130-02 VXP2130-03,VXP2140-03 VXP2130-04,VXP2140-04 VXP2150-06
AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B AS Series Speed Controller: Standard Type Elbow Type (Metal Body) Note) The flow rate characteristics are representative values.
Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3
,|e 4 = \bh unit only (N\6A31 14 only; see page 7) 5 = Foot mounting;pipe tap in body hing 0O = Manilold mounting (NVSA 3114) 01 = 1/8" NPrF 0 SA 31 15, 3125) 02 = 1/4" NPTF (N\6A 3t 15, 3t25) 03 = 3/8" NPTF N\ISA 3135) (X = 1/2" NPTF (N\^sA 31 35, 31 45) 06 = 3/,1" NPTF (N!6A 3145) DIBECTIOI{ALAIBVALYE DIMENSIONS/PARTS LIST SERIES NVSA 3115 NVSA 3115 oPttot{a!l frg. lasE axl 338.
Option Body material Nil N Body only With silencer 1 2 ADC12 (aluminum) SCS14 (stainless steel) For AIR EXH: AN200-02 Connection port size 1/4 (8A) 3/8 (10A) Diaphragm material 02 03 1 PTFE (fluororesin) Symbol Type of operation Thread type FLUID OUT AIR SUP Nil T F N Rc NPTF G NPT Automatically operated type with built-in pulsation attenuator 2 AIR EXH FLUID IN Built-in pulsation attenuator