Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
L R O D T H R E A D X A O P T I O N Thread Form Code M .
Do not connect the earth to a water pipe, a gas pipe, or a lightening rod. Do not plug too many leads into a single socket. That causes exothermic heat or fire. Do not modify the internal electrical wiring of the product. 10.2 Specifications An earth leakage breaker is installed in the product.
L R O D T H R E A D X A O P T I O N Thread Form Code M .
A ARX AMR ARM ARM ARP IR-A A-A X IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ Component Parts Replacement Parts Description No.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
D-B5/B64 D-G5/K59 D-G5W/K59W (A set of band and screw) BA-02 BA-01 (A set of band and screw) BA-32 (A set of band and screw) BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) BA-08 (A set of band and screw) BA-10 (A set of band and screw) Note) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform,
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: Basic Type, Robot Connection Cable: N (without connector cable), Protective Cover: without protective cover, Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: O (Normally Open), Robot Connection Cable: With connector cable, Protective Cover: D (with protective cover), Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: O (Normally Open), Robot Connection Cable: With connector cable, Protective Cover: D (with protective cover), Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: Basic Type, Robot Connection Cable: N (without connector cable), Protective Cover: without protective cover, Manual Changer: F (without main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: O (Normally Open), Robot Connection Cable: With connector cable, Protective Cover: without protective cover, Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: C (Normally Closed), Robot Connection Cable: With connector cable, Protective Cover: without protective cover, Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: Basic Type, Robot Connection Cable: With connector cable, Protective Cover: D (with protective cover), Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: Basic Type, Robot Connection Cable: With connector cable, Protective Cover: without protective cover, Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: Basic Type, Robot Connection Cable: With connector cable, Protective Cover: D (with protective cover), Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: C (Normally Closed), Robot Connection Cable: With connector cable, Protective Cover: D (with protective cover), Manual Changer: E (with main plate assembly)
Compatible Robot: 051 (FANUC: CRX-5iA, CRX-10iA(L), CRX-20iA, CRX-25iA), Switch Selection: P (Auto Switch PNP), Valve Option: O (Normally Open), Robot Connection Cable: With connector cable, Protective Cover: D (with protective cover), Manual Changer: E (with main plate assembly)