B Released Work 1 Work 2 Work n D Peak/Bottom value indication Atmosphere This function constantly detects and updates the maximum (minimum) value and allows to hold the maximum (minimum) pressure value. When the buttons are simultaneously pressed for 1 second or longer, while holding, the held value will be reset.
Ionizer Additional air blow Air blow Ionized air 497 ZVB Series Dimensions C B D A C B A D F E [ZVB20] F E [ZVB40] Model A B C D D Note 1) E F F Note 2) ZVB20 211 202 212 310 351 210 297 341 ZVB40 248 392 298 349 390 400 384 428 Note 1) Dimension D is the overall height including the knob of the regulator.
Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET SY3000 manifold model Ejector valve number Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)
Inlet pressure (MPa) 14-20-5 4 Series AMG Dimensions AMG150 to AMG650 Accessory D: With auto-drain (N.O.) Drain cock: Black One-touch fitting C: With auto-drain (N.C.)
Nil Rc Thread type F G N NPT Accessory/Option Combinations Available Not available Depends on model Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Accessory Option specifications C C D -J -R D J T AMH150 R AMH250 AMH350 AMH450 Applicable model Accessory (Option)
Data (A) Volume of Cylinder/Capacity of Converter 160 140 180 125 300 250 800 700 600 200 Selection Step 100 10,000 8,000 6,000 5,000 4,000 500 400 Step (1) Select the bore size of air-hydro cylinder 80 300 First of all, select a bore size from data (D)
The AL-D series of modular lubricators brings a modern appearance to SMC's line of lubricators while maintaining the high performance of our other series. The lubrication rate is easily adjustable without tools to meet equipment needs. The transparent bowl guard on the size 30 and larger provides improved environmental protection as well as full view of the bowl contents.
The AL-D series of modular lubricators brings a modern appearance to SMC's line of lubricators while maintaining the high performance of our other series. The lubrication rate is easily adjustable without tools to meet equipment needs. The transparent bowl guard on the size 30 and larger provides improved environmental protection as well as full view of the bowl contents.
(example: If the Pressure switch with output impedance of 1 k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5 (V) x 1 (M)/(1 (k) + 1 (M)) 4.995 (V), and there is an error of approximate 0.005 V). Output impedance Operation mode Either hysteresis mode or window comparator mode can be selected.
Remarks Weight Lead wire and M12 connector LFE-1-A3 Lead wire length: 3 m Approx. 175 g LFE-1-D Tapping screw 3 x 10, 4 pcs. Approx. 45 g Bracket LFE-2-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R005 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
Remove Mount Internal circuit D-M9NJ# D-M9PJ# [Note] Please contact SMC if using AND connection. -11No.D-S-OMS0002-B Maintenance How to reset the product for power loss or forcible de-energizing Regarding set up, contents of the program may be maintained by customer's application systems.
(D-M9 only) Operation Environment Recommended Tool Description Model Wire stripper D-M9N-SWY * Stripper for a round cable (2.0) can be used for a 2-wire type cable. Warning (1) Never use in an atmosphere with explosive gases. Auto switches are not designed with explosion-proof construction. Never use in an atmosphere containing explosive gas since this may cause a serious explosion.
MH*-OMM0056 MHS2-D MHS3-D MHS4-D MHSJ3-D MHSH(J)3-D 1. 23 2. 2-1. 45 3. 3-1. 6 3-2. 67 3-3. 713 3-4. 13 3-5. 14 3-6. 14 3-7. 14 4. 4-1. 14 4-2. 1518 4-3. 1922 4-4. 2326 1 [ ][][] ISO4414*1)JISB8370*2) 1) ISO4414Pneumatic fluid power-Recommendations for the application of equipment to transmission and control systems. 2) JIS B8370 2 1. 2. 3. 4. 3 2 2-1 MHS2 MHS2 -16D MHS2 -20D MHS2 -25D
Auto Switch Auto Switch Specifications D-M9-5(With indicator light) Auto switch model D-M9N-5 D-M9P-5 Electrical entry direction In-line Wiring type 3-wire Output type NPN PNP IC circuit, Relay, PLC IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or
CN2TB/PC () 19 - .CN4 6.1 1 EMG+ EMG 2 EMGEMG 3 24V 5 4 3 2 () 4 0V 5 FG FG (LEC)(0V) ULUL1310Class2 6.2 2) AWG20(0.5mm (24V0V) 60 2) EMG AWG20(0.5mm (EMG+,EMG-) 60 8mm 20 - D(100) D 6.3 (CN2SW)ON(EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC) OFF (LEC)(EMG+,EMG-) 21 - (LEC) ( LEC6) DC24V 0V Ry EMG+ Ry EMG(1) BK RLS EMG Ry C 24V 24V
e) 47 - D 100 154 1. 2. 3. 4. 5. 6. 7. 8. -10603585% 48 - 155 5 156 49 - 16/ 161 / UL1310Class2 162 ON 50 - 5 () 51 - 163 50mm 164 () 52 - 165 166 D 100 167 53 - Revision history No.JXC-OMT0030CN 2018 3 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior
REG. (2) (1) Type D: 6 to 8 mm Applicable crimp terminal For lower hamber setting For upper hamber setting Type E/T: 1.25-3, 1.25-3S 1.25Y-3N, 1.25Y-3S (Round or Y shaped crimped terminals can not be used for type D.)
When increasing the number of stations, order the required number of single unit of the body type 3 valve (b) and the required number of either the pressure sensor (d) assembly (c) or the vacuum pressures switch assembly (d).