Connection with tools such as an air driver is also possible. Note) Ensure the TKS does not shake or vibrate. KK Window KK130 Air driver, etc. DM KDM KB 4. Pull the TKS off of the tubing to complete stripping. The tube can be attached as it is to a FR One-touch fitting.
(Type 20 manifold) 10 23 5 M 1 M3 SYJ3 Body ported Base mounted (4 port) 2 10 SYJ3 33 5 M (Manifold use only) Base mounted (5 port) SYJ3 43 M 2 5 10 Clean series 4 port Port size Coil specifications Manual override Nil Standard With power saving circuit <24, 12 VDC only> Nil: Non-locking push type Nil: Without sub-plate T Power saving circuit is not available in the case of "W" type.
Type of actuation Bracket 1 2 Normally closed Normally open (For manifold type 20, 20R) Bracket is mounted.
KE AS-FG Dimensions AS-FP H1 AS-FM (Hexagon width across flats) AS-D Applicable tubing O.D. d AS-T H2 ASP (Hexagon width across flats) L4 L3 ASN L5 AQ ASV D1 L2 AK VCHC M M L1 ASR ASQ Metric Size Inch Size L4 Max. L5 (1) L5 (1) L4 Max. Weight (g) Weight (g) Panel-cut dimensions Panel-cut dimensions H1 H2 d D1 L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M Model Model Min. Max. 34.4 Min.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of th, Thermo-chiller, water cooled, CHILLER, 729, 121 lb
I The dual output applies to NPN, -O~P7:~iP~tio~n~-'-~p~a~m~No~.-.~~===rr-N"~e-_ ~~ =4It PNP, and analog output.
④ The pipe length from the strainer to the liquid collector body is 20 m or more when the mounting height of the liquid collector is 3 m or more for a water-soluble solution or 1 m or more for an insoluble solution.
⑤ The dynamic viscosity of the fluid is too high to flow.
⑥ The operating fluid is air. (Air cannot be used as the fluid.
m]LEHF10K2- 580.260.260.53
(mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
Right hand P411040-8 Left hand P411040-9 3 Series CRB1 Effective Output Direct Mounting of Rotary Actuator CRB1BW63 1Nm=10.2kgfcm 50 52mm Bolt M8 (4pcs.) 40 Effective torque Nm Double vane 30 Single vane 20 10 0 0.2 0.4 0.6 0.8 1.0 0 Operating pressure MPa 1MPa = 145 psi 1Nm = 0.7375 ftlb (Viewed from long shaft side)/Keys in the drawings indicate an intermediate position when the A port
r StJpply + TlIfm..ar r -RIld P()" 'f ~ Te-m"O
106 2 2.3 3.2 6 7 10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 108 155 221 13 16 19 20 22 25 1/4, 3/8 3/8, 1/2 1/2, 3/4 1in = 25.4mm 5
Positioning repeatability is ±5 μm, with an operating rate of up to 500 cycles per minute. Maximum load mass: 1000g (horizontal), 100g (vertical); Maximum pushing force: 5.5N; Strokes: 10, 20, 30 mm; Weight: 130, 190, or 250g (stroke dependent); Positioning repeatability: ±5 µ m (“F” resolution option); Parts measurement repeatability: ±10 µ m (“F” resolution option)
ANA1-01 to 06 ANA1-06: PP How to Order ANA1-01 to 20 A1 03 AN Port size Symbol Port size Connection 01 1 8 02 1 4 03 3 8 04 1 2 Screw-in 06 3 4 1 4 10 1 12 1 1 2 1 14 20 2 Model (One-touch fitting connection) C08 (8 One-touch fittings size) Effective area (mm2) Weight (g) ANA1-C08 11 5 58 16 A B Dimensions (mm) Model One -touch fitting size 8 10 12 C10 (10 One-touch fittings size) One-touch