SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-R-M-02L-WA3Y"

P101. 2 CG5 N A (mm) E max (J) E max (J) 2 E=(m/2)v 20 0.28 0.42 25 0.41 0.65 E J m: (Kg) v m/s 32 0.66 0.91 40 1.2 1.8 50 2.0 3.4 EE max (J) 63 3.4 4.9 80 5.9 11.8 100 9.9 16.7 (2) 2-7. 14 28. 3 13 2 3CDG5 (M4 1~1.2Nm 3 3.

Material: Carbon steel Dd9 d L Part No. m t l 0.040 0.076 CD-S02 CD-S03 20/25 32/40 8 C8 type for pivot 7.6 24.5 19.5 1.6 0.9 0.040 0.076 10 C10 type for pivot 9.6 34 29 1.35 1.15 Applicable bore size 20 25/32 40 Part No.

T0604 How to Order Max. operating pressure Max. operating pressure T 0604 B 20 Length per roll Color Nylon tubing 20 20 m 100 m roll (Black, white only) Operating temperature (C) Symbol Color B W R BU Y G Black White Red Blue Yellow Green Maximum operating pressure is 1/3 max. of burst pressure at 60C, considering the safety ratio. Tube size 100 O.D. 6 I.D. 4 14-13-10

Electric Actuator/Rod Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) LEY16, 25, 32 Series LEY How to Order LEY 16 30 B 1 1 6N S q w e r t y u i o !0 !1 !2 !

G Lead wire length Digital pressure sensor 0.6 m 5 m Nil X202 PPA A variety of installation options Screw includedM5, Mounting bracket M5 type only 8 1 R , 4 1 R Unit specifications AL With the unit switching function Note) Nil M Port size Fixed in SI unit (MPa) M5 01 0 M5 (Female thread) R1/8 R1/4 Note) With unit switching function is not permitted to sell for the domestic use in Japan,

R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) The combination of K, L and M is not possible because an auto drain can only be attached to a single option. 2 The maximum operating pressure is 1.6 MPa. 3 Voltage symbol 20 (200 VAC) is the terminal block connection as standard. The Option S cannot be chosen.

P A B C D G J M N Q R S T U V B AFF50 3/41 90 237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AFF60 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Semi-standard specifications SUS bowl Model No.

P A B C D G J M N Q R S T U V B AM50 3/41 90 237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AM60 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Semi-standard specifications SUS bowl Model No.

P A B C D G J M N Q R S T U V B AMD50 3/41 90 237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AMD60 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Semi-standard specifications SUS bowl Model No.

IS*-OMX0095-B PRODUCT NAME Pressure Switch Pressure Switch with T-Spacer Pressure Switch with L-Piping Adapter Pressure Switch with Piping Adapter MODEL / Series / Product Number IS10M-(20,30,40,50,60)(-1,6,L,P,Z)-D IS10T-(20,30,40,50,60)-(F,N)(-6,L,P,Z)-D IS10L-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D IS10E-(20,30,40,50,60)-(F,N)(-6,L,P,R,Z)-D Contents Page 1. Safety Instructions 2-7 2.

T0604 How to Order Max. operating pressure Max. operating pressure T 0604 B 20 Length per roll Color Nylon tubing 20 20 m 100 m roll (Black, white only) Operating temperature (C) Symbol Color B W R BU Y G Black White Red Blue Yellow Green Maximum operating pressure is 1/3 max. of burst pressure at 60C, considering the safety ratio. Tube size 100 O.D. 6 I.D. 4 14-13-10

Cylinder with Lock Series MNB Taper ring Steel ball P f R R High locking efficiency Improved locking efficiency, as well as stable locking and unlocking (unlocking pressure 0.25MPa. 0.05MPa compared to conventional P/A products) have been realized by arranging a large number of precision steel ball bearings in two circular rows.

3 Ejector assembly ZK2 EJ A W 10 Nozzle nominal size 07 0.7 10 1.0 12 1.2 15 1.5 Bellows type with groove Flat type with groove 257 ZHP Series Dimensions 30 N 70 Silencer In the case of Flat type P 16.6 EXH. 24.7 P F E D C A PD port 3 6.2 K M Female thread mounting M Male thread mounting Unlocked: 32.2 PD port 2 Locked Unlocked J PD port 1 G H P port L E F 6.2 10 7.8 6.2 Lock screw 14.4 1.4

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DA, IFW/PFW 1/4INCH PT VERSION, .66390 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .44092 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .66138 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DA, IFW/PFW 1/4INCH PT VERSION, .61577 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA