at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
Auto switch Auto Switch Specifications D-M9N(With indicator light) Auto switch model D-M9N Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage
Load voltage 12 to 24 VDC10%, Ripple(p-p) 10% or less If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident. 5 to 40 mA Load current Leakage current 1 mA or less Int. voltage drop 5 V or less The following instructions must
Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St.
(D1) TUH/Standard type 4 2.8 6 4.4 8 5.8 10 7.3 12 8.8 I.D. (D2) O.D. (D1) Tubing I.D. (D2) TUH/High pressure type TU 8 2.5 4 5 6.5 1in = 25.4mm Operating pressure 1.0MPa (at 20C) [145 psi @ 68F] TUH/High Pressure Type Same operating pressure as series TS soft nylon tubing, and a bending radius equivalent to series TU polyurethane tubing.
L dimension 11 148 12 160.5 13 173 14 185.5 15 198 16 210.5 17 223 18 235.5 19 248 20 260.5 No. L dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 No.
Applicable cylinder bore size (mm) AS121-M5 Model Port size 4 6 8 10 12 M5 x 0.8 6, 10, 16, 20 Construction 1 8 AS221-01 R 20, 25, 32 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R 40, 50, 63 1 2 AS421-04 R 63, 80, 100 Note) marking is electroless nickel plated, provided as standard.
L1 L2 L3 L4 L5 L6 L7 (1) L8 D Model Bore size ASV AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 5 17 54.5 16 15.5 50 30 10 4.5 AK 1 4 1 4 2 x M4 x 0.7 11.5 17 56 51.5 40 5 23 20 30 4.5 Effective thread depth 6 Reference dimensions 8 3 45.5 5.25 20.6 61 13.2 68 56 25 26 5.5 VCHC Note 1) L7: Reference dimensions Dimensions: AS5000 ASR ASQ 2 x 1/4 to 1/2 2-1/4 to 1/2 74.9 (Max. 82.9)
Rated voltage Manual override Symbol Nil: Non-locking push type A: Non-locking push type (Manual) E: Push-turn locking type (Manual) DC AC (50/60 Hz) 2(A) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] 5 24 VDC 6 12 VDC (P)1 3(R) Electrical entry Light/surge voltage suppressor DC AC Nil Without light/surge voltage suppressor S With surge voltage suppressor *1 DIN terminal
Please note the 12-REA must be used with an external guide to support the load. Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
Please note the 12-REA must be used with an external guide to support the load. Bore sizes: 25, 32 40, 50, 63 mm; Stroke lengths: 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm; Maximum stroke length: 1300 mm (25, 32, 40, 50 & 63 bore); Minimum operating pressure: 0.18 MPa (26 psi); Speed: 50 ~ 300 mm/sec.
No.PF-OMH0003-F PRODUCT NAME 4-channel Flow Monitor (Remote type monitor unit) MODEL / Series / Product Number PF2A20# PF2W20# PF2D20# Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Definition and terminology 13 Mounting and Installation 15 Installation 15 Wiring 16 Outline of setting 19 List of outputs 20 Initialize mode 21 Default
Without bracket (Bottom view) Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13(Z) 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14(Z) 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26(Z) 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38(Z) 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13(Z) 48 39 4.6 12 11.5 52 28
From the graph it is approx. 40%. 2Next, convert it to discharge rate of clean water. 40% of the discharge of clean water corresponds to 200mL/min. of required specification.
(J) 20 25 32 40 0.27 0.4 0.65 1.2 0.11 0.18 0.29 0.52 , (1) 2-7. 1) 2) 3 10 - 2-8.
mA) 4V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage 0.8mA or less 100A or less at 24 VDC 0.8mA or less 100A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 Approx. 45g LFE14 48 39 4.6
Compact Cylinder/Non-rotating Rod: Double Acting, Single Rod Series CQ2K Replacement Procedure is 12, 16, 20, 25 32, 40, 50, 63 P.290 Construction Standard (40 to 63) !4 !5 !3 !4 !5 !3 With auto switch Without auto switch The numbers are the same as the "Construction" of the CQ2 series catalog (CAT.ES20-205). *BLUE links will lead to purchase pages.
Compact Cylinder/Non-rotating Rod: Double Acting, Double Rod Construction Series CQ2KW 12, 16 20, 25 32, 40 50, 63 Replacement Procedure is P.290 Standard (40 to 63) Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !6 !8 !5 !7 !6 !8 !5 !
Compact Cylinder/Standard Type: Double Acting, Double Rod Construction Series CQ2W 12, 16, 20 25, 32, 40 50, 63, 80 100 Replacement Procedure is P.290 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !1 !3 !2 !1 !3 !