SMC Corporation of America
Elite Part Number Search
Search Results "AMG550C-N10B-H"

.: Uni-wire H System Note 1) DN1s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.

Removing Loosen clamp ring (1), and separate the multiconnector into two parts, multiconnector into two parts, socket side and plug side. (1) Clamping ring K (3) Case B M D H Insertion and removal of tube D + Driver (5) Barb (6) Clamp bolt (3) Case (2) Stopper Connection 1.

VK VZ VF Manual override (Non-locking) G: 300 mm H: 600 mm (Lead wire length) (3 port valve) VFR (A port) VP4 VZS VFS (Pitch) (Mounting hole) VS4 4-Rc 1/8 (P , R port) (A, B port) VQ7 EVS VFN 4-M3 x 0.5 depth 4.5 (Bracket mounting screw) (mm) Stations 2 3 53 40 69 56 4 85 72 5 101 88 6 117 104 7 133 120 8 149 136 9 165 152 10 181 168 11 197 184 12 213 200 13 229 216 14 245 232 15 261 248

A A B C D E F G H B C D E F Pressure port Pressure port Right Left Left Right Right Left Left Right Right Left Left Right Left Right Operating direction Operating direction There are 9 possible reciprocating piping methods. There are 16 possible reciprocating piping methods.

B and H cannot be selected at the same time. The current bracket cannot be used for this product. Note 2) Assembly of a bracket and set nuts. Note 3) See pressure unit table below.

H Anti-chattering function (F3) A large bore cylinder or ejector consumes a large volume of air in operation and may experience a temporary drop in the supply pressure. This function prevents detection of such temporary drops in the supply pressure as an error.

CE compliant 1 Note) 3 Note) 5 6 V S R Nil 100 VAC 50/60 Hz 110 VAC 50/60 Hz 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Air operated/Without valve Nozzle diameter Standard supply pressure MPa Combination of Nozzle Diameter and Standard Supply Pressure H (0.5) M (0.35) S (0.45) 0.5 mm 0.7 mm 1.0 mm 1.3 mm 1.5 mm Note) CE compliant products are not available for 1 and 3. 986

Note 3) When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select wiring top entry for the lead wire entry. (Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring.

Note 3) When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select wiring top entry for the lead wire entry. (Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring.

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing CY1L Series 6, 10, 15, 20, 25, 32, 40 How to Order Ball Bushing Bearing H 300 J79W CY1L 25 Refer to page 1517 for details. Slider type (Ball bushing bearing) Number of auto switches Auto switch Bore size Nil 2 pcs.

Motorless Type Electric Actuator/Slider Type Ball Screw Drive LEFS Series LEFS25, 32, 40 How to Order LEFS 100 A 25 q e y NZ w r t H R q Accuracy r Motor type e Motor mounting position y Stroke [mm] t Lead [mm] Nil Basic type H High precision type 50 50 to to 1200 1200 Nil In-line R Right side parallel L Left side parallel Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 Symbol

Fluoropolymer Fittings Hyper Fittings LQ1 Series RoHS How to Order LQ1 H M 11 Threaded connection Thread type Symbol Nil N Fitting type Symbol H L R B Type R, Rc NPT Type Connector Elbow Run tee Branch tee Packaging Symbol Packaging Piping type Symbol M F Clean packaging equivalent to Class M3.5 Standard packaging equivalent to Class M5.5 Nil Type Male Female 1 Size combination For different

Note 3) When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select wiring top entry for the lead wire entry. (Select wiring bottom entry when the semi-standard Y is chosen simultaneously.) Note 4) The only difference from the standard specifications is the pressure regulator spring.

H Clean One-touch fittings D MS Applicable tubing O.D.

KPQ/KPG Series Clean One-touch Fittings How to Order KP H 06 KP P 08 Q 01 KQ2 Applicable fitting size Clean One-touch fittings Made to Order KQB2 04 06 08 10 12 4 6 8 10 12 Specifications X53 With pipe tape Grease-free Symbol Q G KS KX Specifications (metal part materials) Brass (electroless nickel plated) Stainless steel 304 Rubber material: EPDM (Fluorine-coated) X193 Note 1) Gasket: M-

mm) DIN terminal DIN terminal (Without connector) Nil Without sub-plate H D DO 2 01 1 8 1 8 Base mounted 02 1 4 1 4 Caution Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.

LE-CSM-Rmm is MR-PWS1CBLmM-Am-H manufactured by Mitsubishi Electric. LE-CSB-Rmm is MR-BKS1CBLmM-Am-H manufactured by Mitsubishi Electric.

Port 3/4 3/4, 1 D I M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER

(Tampa) 8507-H Benjamin Road Tampa, FL 33634 Tel: (813) 243-8350 FAX: (813) 243-8621 SMC Pneumatics Inc. (Houston) 9001 Jameel, Suite 180 Houston, TX 77040 Tel: (713) 460-0762 FAX: (713) 460-1510 SMC Pneumatics Inc. (Portland) 14107 N.E. Airport Way Portland, OR 97230 Tel: (503) 252-9299 FAX: (503) 252-9253 SMC Pneumatics Inc. (Cincinnati) 4598 Olympic Blvd.