SMC Corporation of America
Elite Part Number Search
Search Results "ISA3-GCP-4NB-L5"

Number of stations: 4 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable

Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Cable: None

Number of stations: 2 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Cable: Centralized lead wire (with bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: Straight, Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None), Bracket Option: B (Bracket)

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: M (Fixed SI Unit), Stations: 1

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: S (Centralized Lead Wire, Lead Wire Only), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None), Bracket Option: B (Bracket)

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, INSTRUMENTATION, IS300 PRESSURE SWITCH, DA, IS300 1/4INCH PT VERSION, .46438 lb, ModelPiping methodMicro switch typeMin. applicable loadIS3110Gasket pipingMicro load5 VDC 1 mA

Pneumatic pressure switch series IS3000 can be used for small electrical loads of 10mA such as relays and programmable controllers. IS3000 has a high frequency operation of 1 cycle/sec and a long life of 10 million cycles due to piston construction. Calibration ranges from 0.1 to 0.7 MPa., PRESSURE SWITCH, INSTRUMENTATION, IS300 PRESSURE SWITCH, DA, IS300 1/4INCH PT VERSION, .51440

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port

Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R1 (w/Control Unit, Supply Port

Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply