Doc. no.VM*-OMR0038-B PRODUCT NAME Time Delay Valve MODEL / Series / Product Number VR2110 Contents Page 1. Safety Instructions 2 ~ 9 2. Application 10 3. Specifications 10 4. How to Order 10 5. Operation Patterns 11 6. Characteristics 11 ~ 12 7. Dimensions 13 1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
(1) When using the KFG2-F series with tubing other than those from SMC, the products are not subject to warranty. 9 - 3.
Recommended tightening torque Unit: Nm Connection thread 3/4 28 to 30 1/8 7 to 9 1/4 12 to 14 3/8 22 to 24 1/2 28 to 30 1 36 to 38 Torque 5-8-23
Make sure to perform a maintenance periodically on air filter and mist separator (by discharging the drain and cleaning a filter element or replacing with new one). 6 VY-OMK0001-C VY1 Series Specific Product Precautions 2 Be sure to read this before handling. (1) (1) (1) Note 1) Not conforming to ISO1179-1. (2) Note 2) Gasket and mounting bolts are equipped. DIN connector part no.
industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993: *2) : : : 1. 2. 3. 1. 2. 3. 4
Attached to product (2 pcs each) Regarding the TSJ fittings, after tightening the nut by hand, add another 1 1/4 to 1 1/2 turns with a wrench to seal the fitting. In case the fitting is re-installed after filter replacement, first tighten the nut by hand and add another 1/4 to 1/2 turns for sealing. Use the following parts as piping and fittings.
Table 1 Bonnet assembly/construction part number:1 Valve size Temperature specifications 16 25 40 50 Standard(5150) XLH16-30-1 XLH25-30-1 XLH40-30-1 XLH50-30-1 Note1) List the optional seal material symbol after the model number, except for the standard seal material (FKM: compound no. 1349-80).
Regarding the TSJ fittings, after tightening the nut by hand, add another 1 1/4 to 1 1/2 turns with a wrench to seal the fitting. In case the fitting is re-installed after filter replacement, first tighten the nut by hand and add another 1/4 to 1/2 turns for sealing. Use the following parts as piping and fittings.
Attached to product (2 pcs each) Regarding the TSJ fittings, after tightening the nut by hand, add another 1 1/4 to 1 1/2 turns with a wrench to seal the fitting. In case the fitting is re-installed after filter replacement, first tighten the nut by hand and add another 1/4 to 1/2 turns for sealing. Use the following parts as piping and fittings.
T Conduit terminal Refer to the table (1) given below for availability. Rated voltage 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Model Port size (Rc 1/4) (Rc 3/8) (Rc 1/2) (Rc 3/4) (Rc 1) 02 03 04 06 10 2232 2232 2242 2352 2362 4 5 6 7 8 9 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC for inquiry.)
They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems. IEC 60204-1: Safety of machinery -Electrical equipment of machines.
Regarding the TSJ fittings, after tightening the nut by hand, add another 1 1/4 to 1 1/2 turns with a wrench to seal the fitting. In case the fitting is re-installed after filter replacement, first tighten the nut by hand and add another 1/4 to 1/2 turns for sealing. Use the following parts as piping and fittings.
2.4 0.60 0.12 2.8 1 4 VFS Double check VZS3650 420 32 or less 0.43 1.2 1.1 1 4 VS4 Note 1) Min. operating cycle is based on JIS B 8375 (One time per 30 days).
1 1 2 5 2-1. 5 2-2. 5 2-2-1. 5 2-2-2. 5 2-2-3. 6 2-3. 6 3 3-1. 7 3-2. 7 4 4-1. 8 4-2. 8 4-3. 8 5 5-1. 9 5-2. 10 5-3. 10 6 6-1. 11 6-2. 12 CEP1B12 13 CEP1B20 14 , 1 ,, , ,ISO4412 *1)JIS B8370 *2) ,, , ,, *1) ISO 4414 Pneumatic fluid power-Recommendations for the application of equipment to transmission and control systems. *2) JIS B8370
Caution How to Use DIN Terminal Precautions 1. Disassembly 1) After loosening the screw (1), then if the housing (2) is pulled in the direction of the screw, the connector will be removed from the body of equipment (solenoid, etc.). 2) Pull the screw (1) out of the housing (2). 3) On the bottom part of the terminal block (3), theres a cut-off part (9).
M3 hexagon screw Tightening torque 0.6 Nm 1 1 1 1 0 1 62 The technical document states detail troubleshooting information can be found on the SMC website (URL http://www.smcworld.com) 1 1 1 1 1 1 63 *: Thread size: M330 If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation.
MODEL / Series / Product Number JMHZ2-16D-X7400B Contents Safety Instructions . 2 1. List of included items . 4 2. Parts description of the air gripper . 5 3. Product Specifications . 6 3-1. How to order . 6 3-2. Specifications . 6 3-2. Gripping force . 7 3-3. Gripping point . 8 3-4. Dimensions (when the cover and attachment are mounted) . 9 3-5. Connector and pin layout . 9 3-6.