SMC Corporation of America
Elite Part Number Search
Search Results "CDM2B25-200+100Z-XC10"

C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut

C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut

Inrush current: No breaking at the current values shown in the table for 20 ms. 3-6 3 Wiring and Connection 3.1.3 Using the DRIVER with Single-phase, 200 V Power Input LECYM2 series three-phase 200 V power input DRIVER can be used also with a single-phase 200 V power supply.

The upper limit for the actual time of the arc part is as follows: At acceleration: 20 STA , At deceleration: 20 STB (Example) Settings of STA = 20, STB = 5000 and STC = 200 limit the actual arc part times as follows: 20 20 Since =100[ms]<200[ms], At acceleration: 100 [ms] the time is limited to 100[ms]. 20 5000 Since =400[ms]>200[ms], At deceleration: 200 [ms] the time is as-is.

VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and

HRSH150/200-A: 2 pcs. are used per unit HRS-S0214 Dust-proof filter (Upper) 1 pc. HRSH100/150/200-A: 2 pcs. are used per unit HRS-S0185 Dust-proof filter 1 pc.

mm/s or less L = 100 mm, V = 200 mm/s or less 10 10 Load mass m [kg] Load mass m [kg] 1 1 0.3 0.3 10 30 31 101 200 100 10 30 31 100 101 200 Stroke [mm] Stroke [mm] MGPKL32 L = 50 mm, V = 200 mm/s or less L = 100 mm, V = 200 mm/s or less 50 50 Load mass m [kg] Load mass m [kg] 10 10 3 3 10 50 51 100 101 200 100 101 200 10 50 51 Stroke [mm] Stroke [mm] 21 Model Selection MGPK Series L L Plate

(Adjustable) Hysteresis Data ON: when output is ON (Red) ON: when output is ON (Red) ON: when output is ON (OUT1: Red, OUT2: Green) Indicator light Trimmer adjustment 3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees None 1 to 5 V 5% F .S.

0 100 200 300 400 500 600 700 0 50 100 150 200 250 0 50 100 150 200 250 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) 238 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SLOVENIA SMC Slovenia d.o.o.

/200 to 220VAC (50/60Hz) Single phase, 220, 240/200 to 240VAC (50Hz) Power source 225 275 205 240 182 189 250 350 220 280 265 275 305 380 300 350 280 295 340 415 325 375 332 50Hz 60Hz 50Hz 60Hz 50Hz 50Hz 50Hz 100 VAC 200 VAC Power consumption (W) 220 to 240VAC 220VAC 240VAC JIS Symbol 10 (for 100VAC), 5 (for 200VAC) Air cooled R134a Circuit breaker (A) Note 3) Refrigerated air dryer

to 300 200 to 1400 200 to 2000 200 to 2000 75 to 150 50 to 1200 50 to 2000 50 to 2000 15 200 to 300 200 to 1400 150 to 2000 100 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 20 150 to 250 150 to 1300 100 to 2000 50 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 30 50 to 200 50 to 1300 50 to 2000 50 to 2000 50 to 125 50 to 1100 50 to 2000 50 to 2000 effect before installing. 3-1-

Nil 3 rotations setting 200 setting 3 rotations setting 200 setting 3 rotations setting 200 setting 18 rotations setting 18 rotations setting E14 1 point setting E15 With analog output 2 points setting E16 E17 Electronic (12 to 24 VDC) 1 point setting E18 E19 With analog output With analog output With analog output Switch model 1 point setting M15 Diaphragm solid state switch (10 to 26 VDC

S Bore size/Stroke (mm) n pcs. n (25), 50, 75, 100 10 (25), 50, 75, 100, 125, 150, 175, 200 16 Auto switch (25), 50, 75, 100, 125, 150, 175, 200 20 Nil Without auto switch (25), 50, 75, 100, 125, 150, 175, 200 25 For the applicable auto switch model, refer to the table below. (25), (50), 75, 100, 125, 150, 175, 200 32 Note1) For the strokes indicated in the parentheses of the 10, 16 and 25

Electrical entry 24, 12 VDC/ 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC 24, 12, 6, 5, 3 VDC/ 100, 110, 200, 220 VAC Gasket assembly part no.

S Bore size/Stroke (mm) n pcs. n (25), 50, 75, 100 10 (25), 50, 75, 100, 125, 150, 175, 200 16 Auto switch (25), 50, 75, 100, 125, 150, 175, 200 20 Nil Without auto switch (25), 50, 75, 100, 125, 150, 175, 200 25 For the applicable auto switch model, refer to the table below. (25), (50), 75, 100, 125, 150, 175, 200 32 Note1) For the strokes indicated in the parentheses of the 10, 16 and 25

CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 140 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 1000 mm 160 180 200 0 100 200 300 400 500 600 700 800 900 1000 Average speed [mm/s] ZK2 Combination Manifold Fittings, Replacement Parts, Tools Manifold Options Specific Product Precautions * Values at extension of a directly coupled cylinder when meter-out speed

LECSS-S5 200 to 1500 *3 Refer to the applicable stroke table for details.

100 0 SX3140-01 900 800 700 600 500 400 300 200 100 0 SX5140-02 900 800 700 600 500 400 300 200 100 0 SX7140-03 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.

kg] Work load [kg] Work load [kg] Work load [kg] 200 200 200 200 160 160 160 160 L4 L4 [mm] L4 [mm] L4 [mm] L4 [mm] 120 120 120 120 X 80 80 80 80 Me m 40 40 40 40 0 0.2 0.4 0.6 0.8 1 0 0 0.0 0.4 0.8 1.2 1.6 2.0 0 0.0 0.4 0.8 1.2 1.6 2.0 0 0 0.2 0.4 0.6 0.8 1 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 200 200 200 200 Me 150 150 150 150 L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 100

Manual override operation Solenoid valve for 200/220 VAC specifications Warning Warning Solenoid valves with grommet and L/M type plug connector AC specificatinos have a built-in rectifier circuit in the pilot section to operate the DC coil. With 200/220 VAC specification pilot valves, this built-in rectifier generates heat when energized.