Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-7 Cooling capacity 5-6 Operation 2) Heating capacity Recirculating fluid flowrate5L/min Ambient Temp.20 Fluid water 1000 Heating capacity W Radiating water Temp.
Indication resolution How fine the rated pressure range can be displayed (example: If a product for 0 to 1 MPa can display pressure by 0.001 MPa, the display resolution is 1/1000.) Indicator LED The LED that turns on when the switch output is on. Indication unit The unit of pressure used on the display.
The part number for bracket assembly for 1000 cm3 is AF50P-050AS (applicable to the AL30 to AL60).
V = 2gH/1000 x 60 Obtain the total amount of the workpiece. Total weight m = 10 x 0.1 (kg) = 1 (kg) Obtain the intersection of the transfer speed V and the total weight of workpiece m.
AS2301F-02, AS2311F-02 AS2201F-02, AS2211F-02 AS3201F, AS3211F AS4301F, AS4311F AS4201F, AS4211F AS3301F, AS3311F Supply pressure: 0.5MPa Supply pressure: 0.5MPa Supply pressure: 0.5MPa 16 25 6 400 1000 14 10, 12 1500 12 80, 10 20 12 Effective area (mm2) Effective area (mm2) 08 06 Effective area (mm2) 300 10 Flow (l/min(ANR)) Flow (l/min(ANR)) Flow (l/min(ANR)) 06 10 1000 4 15 500 8 04 200
1000 MQML: Standard type MQMLH: High speed/High frequency type Maximum speed V(mm/s) Note 1) When a load is attached to the rod end, adjust the speed so that the maximum speed is no more than that shown in the graph for the corresponding load weight.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and deenergized states in the axial direction and at the right angles to the main valve and armature.
1100 1200 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end (mm/s) Speed at the end (mm/s) Applicable related components Applicable related components For details regarding different conditions, make determinations after using the SMC Model Selection Program Pneumatic Cylinder Drive Systems.
How to order L/M connector assembly Lead wire length Positive common specifications For single solenoid: SX100 40 4S B port N.C A port N.O Plug position Actuation Nil 300 mm Plug Plug 6 600 mm For double solenoid: For 3 position SX100 40 4D 10 15 20 25 30 50 1000 mm Number of solenoids 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Single Negative common specifications For single solenoid: SX100
Without lead wire Nil 6 10 15 20 25 30 300 600 1 2 3 Blue (2) For 100 VAC For 200 VAC Another VAC 1000 1500 2000 2500 3000 Socket Hook Red (2) Gray (2) 4 Red: +, Black: For DC Note) When ordering a valve in which the length of the wire is more than 600 mm, be sure to indicate the model number of valve without connector and connector assembly. Ex.)
Handle operated type Air operated type VBA1110 VBA200 VBA400 Model AV Max. 2 Pressure increase ratio VBA2200-03 VBA4200-04 VBA1110-02 VBA1-02 VBA2100-03 VBA4100-04 Note) 400 60 1000 1900 1000 1900 Max. flow (l/min (ANR)) VBA1 2 to 4 AU 1/2 (IN/OUT) 1/4 (IN/OUT) Connection port size Rc 3/8 (IN/OUT) 3/8 (IN/OUT) 1/2 (IN/OUT) Fluid Compressed air 1/4 Exhaust port size Rc 3/8 1/2 1/2 3/8 VBA1110
1200 1400 1600 1600 0 0 200 400 600 800 1000 1200 1400 Flow rate l/min (ANR) Flow rate l/min (ANR) ARBQ4000-00-P (PA) ARBQ4000-00-P (PB) 0.7 0.7 0.6 0.6 Downstream pressure MPa Downstream pressure MPa 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 200 400 600 800 1000 1200 1400 1400 0 0 200 400 600 800 1000 1200 Flow rate l/min (ANR) Flow rate l/min (ANR) 1MPa = 145 psi Nl/min X 0.035 = SCFM
Tight mounting is possible for panel mount in vertical or horizontal position. 34.5 103.5 Compact profile Setting/Display resolution: 1/1000 More user-friendly controls Compound pressure: 0.2kPa Positive pressure: 0.001Mpa Raised rubber button controls are clearly set apart, simple to operate, soft to the touch.
S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1. Material HNBR: Nitrile hydride rubber 500 700 500 1000 1500 800 1000 1200 1000 500 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 500l/min (ANR) is P = 0.64MPa for a 3 orifice, and P = 0.35MPa for a 4 orifice.
1000 1000 800 800 Smooth exhaust valve T msec 600 600 400 400 200 200 0 0 25 40 50 63 80 25 40 50 63 80 Size Size Response time when closed (including pneumatic valve) Operation time when closed (vacuum valve only) Response time when open (including pneumatic valve) Operation time when open (vacuum valve only) 35 Series XL High Vacuum Angle Valve 2 As a function of pilot pressure 1MPa =
Lead wire length Nil 6 10 15 20 25 30 300 mm (Standard) 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm How to order When requiring a vacuum unit equipped with valves with lead wires of 600 mm or more, specify the vacuum module valves without the standard connectors and order the required connector ass'ys separately. Example) ZR120S1-K15MZ-EC . 1 pc.
VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.
These values orove to de convenient and practical lor ejector sizing purposes. l V = 1 x d ' x ' 4 1000 inside diameter ot tubing (mm), tubing length (meters, m), the lesser capacity of llow, O, or O.
E/P Pressure Regulator Manufacturing Pneumatics Worldwide Electro-Pneumatic Regulator Compliant Electronic Vacuum Regulator How to Order ITV 2030 SEN DUQ00833 2 X26 Port Size 1 2 3 4 1/8 (1000) 1/4 (1000, 2000) * 3/8 (2000, 3000) * 1/2 (3000) Body Size 1010 1030 1050 2010 2030 2050 2090 3010 3030 3050 Made to Order * Note: 2090 available with 1/4 port only.
Supersonic cleaning Drying Double-packing Sensor Clean room class 1000 Shipment 381 For Deionized Water and Chemical Liquids Digital Flow Switch PF2D Series RoHS How to Order Remote Type Sensor Unit PF2D5 13 20 1 C Flow rate range Option (Refer to page 391.) 04 20 40 None e-con connector x 1 pc.