SMC Corporation of America
Elite Part Number Search
Search Results "LECP1P1-LEFS40A-1000"

Minimum Bending Radius (mm) 1/8 9.4 5/32 12.7 3/16 19.1 1/4 25.4 5/16 31.8 3/8 38.1 1/2 50.8 5/8 63.5 3/4 76.2 Minimum Burst Pressure (psi) at 24C (75F) 1000 1200 1200 1200 1000 1000 950 900 800 Material Nylon 12 (Polyamide) *Note: Recommended operating fluid and temperature range provides best performance and longest life.

These values orove to de convenient and practical lor ejector sizing purposes. l V = 1 x d ' x ' 4 1000 inside diameter ot tubing (mm), tubing length (meters, m), the lesser capacity of llow, O, or O.

Flow Rate Characteristics Relief Characteristics IR3220-04-A Supply pressure: 0.7 MPa IR3220-04-A Back pressure: 0.7 MPa 0.7 0.7 0.6 0.6 Set pressure [MPa] Set pressure [MPa] 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 1000 2000 3000 4000 5000 6000 0 0 1000 2000 3000 4000 5000 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics Supply pressure: 0.3 to 1.0 MPa Set pressure

Refer to the LECA Operation Manual for installation. e CC-Link direct input type (LECPMJ) is not CE-compliant. t Lead [mm] Symbol LEFS16 LEFS25 LEFS32 LEFS40 A 10 12 16 20 B 5 6 8 10 y Stroke [mm] 50 50 to to 1000 1000 * Refer to the applicable stroke table.

Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 Accessories (Options) 25 to 1000 25 to 1000 25 to 1300 Bracket pin, Knuckle bracket, Knuckle pin, Knuckle, Y-type knuckle, Rod end nut 25 to 1500 50 to 1300 Refer to pages 408 and 409 for part numbers and dimensions. 50 to 1500 Note) Refer to pages 232 and 233 to determine stroke limitation depending

Symbol LEFS16 LEFS25 LEFS32 LEFS40 A 10 12 16 20 B 5 6 8 10 Stroke [mm] 100 100 to to 1000 1000 Refer to the applicable stroke table. [UL-compliant products] When conformity to UL is required, the electric actuator and controller/driver should be used with a UL1310 Class 2 power supply.

Note 11) If the product is used at altitude of 1000 m or higher, refer to Operating Environment/Storage Environment (page 210) Item 14 * For altitude of 1000 m or higher. 198 A

Fig. 9-6 EX9-AWTS -38No.EX-OMY0014-A For power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0x0-S EX500-AP0x0-A Item Specifications Pin No.

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. K Key lock function Function that prevents changes to the settings of the Pressure switch (disables button operation).

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. K Key lock function Function that prevents changes to the settings of the Pressure switch (disables button operation).

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. K Key lock function Function that prevents changes to the settings of the Pressure switch (disables button operation).

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. K Key lock function Function that prevents changes to the settings of the Pressure switch (disables button operation).

(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. 11 - NO. ZQ-OM01501 No.

12 11 10 9 8 7 6 5 4 3 2 1 0 Data Pressure measurement value Diagnosis OUT2 OUT1 Unit specification and pressure measurement value (PD) Series Unit Rated pressure range Display / settable range MPa 0 to 1.0 -0.105 to 1.050 * kPa 0 to 1000.0 -105 to 1050 kgf/cm2 0 to 10.197 -1.07 to 10.71 ISE20B bar 0 to 10.000 -1.05 to 10.50 psi 0 to 145.04 -15.2 to 152.3 Pressure measurement value (PD) 1000

Rough adjustment mode (0, 0.2, 0.5, 1, 2, 5, 10, and 20s) and fine adjustment mode (200 to 1000 ms, incremented by 5 ms). Fluctuation of pressure display and analogue output can be reduced by increasing the set value of the digital filter. The chattering of the switch output can also be reduced.

The part number for bracket assembly for 1000 cm3 is AF50P-050AS (applicable to the AL30 to AL60).

Outlet pressure MPa 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 500 1000 1500 4000 6000 8000 2000 10 0 0 Flow rate L/min (ANR) Flow rate L/min (ANR) AC40 Rc 1/2 Specific Product Precautions 0.6 0.5 Outlet pressure MPa Mounting and Adjustment Air Supply 0.4 Caution 1.

JIS symbol Auto switch model D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 25 to 1000 25 to 1000 25 to 1300 25 to 1500

VAC for 1 min. between external terminals and case Insulation resistance 50M or more (500 VDC Mega) between external terminals and case Vibration resistance 4.9 m/s2 Impact resistance 490 m/s2 to X,Y,Z directions 3 times for each Noise resistance 1000 Vp-p, Pulse width: 1 s, Rise time: 1 ns Weight 140 g (without lead wire) 225 g (without lead wire) Port size 3/8 inch tube 1/2 inch tube

Auto switch types D-A3, D-A44 D-G39, D-K39 D-A5, D-A6, D-A59W, D-F5, D-J5 D-F5W, D-J59W, D-F5NT, D-F5BA, D-F5F D-B5, D-B6 Bore size (mm) 40 50 63 80 100 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-08 BA-10 BT-04 BT-06 BT-06 BT-08 BT-08 Standard Strokes Standard strokes (mm) Bore size (mm) 40 50 63 80 100 125 160 25 to 800 25 to 800 25 to 800 25 to 1000 25 to 1000 25 to 1000 50