Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: None, Combination of Supply and Release Valve: E (Supply Valve: N.O.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar), Pressure Sensor
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar
Nominal Nozzle Size: 07 (ø0.7), Vacuum Port, Supply Port: C8 (Metric; Vacuum Port: ø8; Supply Port: Plug), Exhaust: P (Port Exhaust), Exhaust Sealing Valve: V (Exhaust Sealing Valve), Combination of Supply and Release Valve: A (Supply Valve: N.C.; Release Valve: N.C.), Rated Voltage: 5 (24VDC), Light/Surge Voltage Suppressor: U (Light: Yes; Surge Voltage Suppressor: Yes; Common Spec: Non-polar
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: C8 (Body Ported ø8 One-touch Fitting), Thread: F (G)
Model: 10S (Side Ported), SI Unit Specification: EB (EtherNet/IPâ„¢, 16 Outputs, M12 Connector), SI Unit Output Polarity: Positive Common, Valve Stations: 8 Stations, P, E Port Location: B (Both Sides, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Actuation: 2 (2-Position Double), Barrier: w/o Barrier, Electrical Entry: TT (Cable Type), Lead Wire Length: 30 (3000mm), Manual Override: Non-Locking Push, Port Size: C8 (ø8 One-touch fitting), Thread Type: F (G), Bracket: F2 (w/Side Bracket)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)
Model: 10 (Side Ported), Connector Type: F (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 3 Stations, P, E Port Location: D (D Side), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 0 (w/o DIN Rail with Bracket)
Model: 10 (Side Ported), Connector Type: FW (D-sub Connector, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 7 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: Q (DeviceNetâ„¢), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting)
Model: 10S6 (Side Ported), SI Unit: Q (DeviceNetâ„¢), SI Unit Common, End Plate: 2 (Positive Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 4 Stations, P,E Port, SUP/EXH Assembly: D (Port Location D Side, Internal Pilot), A, B Port Size: C8 (ø8 One-touch Fitting)